SR3 Type 1 Technical Manual
TSP005.doc Issue 5.0 – Jan 2005
Money Controls 2005. All rights reserved.
Page 15 of 50
8. DIL Switch Options.
There are a number of options which can be selected via the 6 way DIL switch.
The 6 way DIL switch or Program Switch Bank can be used for field programming the following:
¾
Enable / disable a specific coin.
¾
Adjust coin security settings.
¾
Bank
select.
¾
Enable / disable alarm.
¾
Teach and Run
TM
.
¾
Erase all windows.
Table 4: DIL Switch Functions
1
2
3
4
5
6
Program 1
Program 2
Program 3
Program 4
Teach on/off
Security
on/off
Table 5: SR3 DIL Switch Guide
SW1
SW2
SW3
SW4
SW5
SW6
FUNCTION
off
off
off
off
off
off
*
Test credit accumulator
off
ON
off
off
off
off
Enable bank 1 and bank 2
ON
ON
off
off
off
off
Enable a coin
off
off
off
ON
off
off
Disable alarm
ON
off
off
ON
off
off
Enable alarm
off
ON
off
ON
off
off
Erase all windows ( Step 1 )
ON
off
off
off
off
off
Erase all windows ( Step 2 )
ON
ON
off
ON
off
off
Inhibit a coin
off
off
ON
ON
off
off
Enable bank 1 only
ON
off
ON
ON
off
off
Enable bank 2 only
* NOTE:- If all the switches are OFF and the reject lever is pressed within 20 seconds of power
being applied, the SR3 will enter “Test credit accumulator” mode, even though one may not be
fitted. The LED will turn RED and no coins will be accepted.
To exit this mode either remove power and re-apply or wait a further 20 seconds and the SR3
will automatically reset.