5. General instructions for users of Ahti and Ukko heaters

Note

Electrical connections may only be carried out by an electrician with valid installation authorization 
according to the current regulations. The Ahti and Ukko electric heaters are suitable for use in a family 
sauna, one (1) heater per sauna room. Retain the installation and operating instructions for further 
reference.

Installation cable

Use rubber cable H07RN-F as a connection cable.

Additional connection options

Control of electric heating with the heater: The electric heating control cable is brought directly 
to the heater’s junction box and further to the heater’s terminal block with a rubber cable that is 
dimensionally identical to the incoming cable.

NOTE! Failure to observe the connection instructions may result in a risk of fire!

NOTE! Remove all plastic film before using the heater!

6. Things to keep in mind when using the heater

Preheating

Stack the heater stones according to the instructions. 

Before you start using the heater, you need to 

preheat the heater two consecutive times

 (follow the same procedure also when the heater blocks are 

replaced). In the first preheating, the heater will be heated for twenty minutes with the temperature 
control set to the middle position. 

Let the heater cool down completely before the second, 40-minute 

preheating session

, in which the temperature control is set to the ¾ position. During preheating, the 

resistors may emit fumes, so please ensure that the room is properly ventilated. 

Do not throw water 

on the heater during preheating

. Always monitor the preheating runs! If preheating is not carried out 

in accordance with the instructions, the soapstone warranty will become void.

Sauna room

Always check the sauna room before switching the heater on! Always make sure that the timer has 
switched the power off after the set time period!

Temperature control

The temperature is adjusted by means of a mechanical thermostat (see page 11). The actual heating 
time depends on the dimensions, structure and thermal insulation of the sauna. The temperature 
in the sauna room can be maintained at the desired level with the thermostat. If the temperature of 
the sauna room becomes dangerously high for any reason, the overheating protector will switch the 
heater’s power off. The cause of overheating must always be investigated. The power can be switched 
on again by pressing the overheating protector reset button (see page 4, item 6).

Summary of Contents for Ahti 6.0

Page 1: ...Installation and Operating Instructions Ahti and Ukko heaters 12 2017...

Page 2: ...installation 8 5 General instructions for users of Ahti and Ukko heaters 9 Note 9 Installation cable 9 Additional connection options 9 6 Things to keep in mind when using the heater 9 Preheating 9 Sa...

Page 3: ...e sauna should be supervised Benches and floors may be slippery therefore move in the sauna with caution Do not go to a hot sauna under the influence of narcotic substances alcohol drugs narcotics etc...

Page 4: ...4 Installation and Operating Instructions Ahti Ukko 2 Ahti and Ukko heaters Ahti heater 6 0 kW and 8 0 kW Ukko heater 6 0 kW 8 0 kW and 10 5 kW...

Page 5: ...mponents 1 Background stone 2 Small heater stones 3 Steel shelf 4 Side stone stainless steel 5 Front and side bottom stones stainless steel 6 Overheating protector reset switch 7 Thermostat 8 Time swi...

Page 6: ...Attach the heater to the wall with screws Observe the safety distances between the heater and any inflammable material in accordance with Table 4 4 see Figure 3 3 when installing the heater 3 Install...

Page 7: ...he shelf see Figure 3 6 5 Attach the background stone see Figure 3 7 6 When stacking the stones ensure that you do not place small heater stones among the resistors or on top of the ventilation grill...

Page 8: ...ed quantity of stones Table 4 2 6 0 kW 8 0 kW 10 5 kW A 220 220 365 B 310 310 435 C 275 275 310 D 140 206 260 E 615 615 780 F 103 130 Attachment points in corner installations Table 4 5 Attachment poi...

Page 9: ...o when the heater blocks are replaced In the first preheating the heater will be heated for twenty minutes with the temperature control set to the middle position Let the heater cool down completely b...

Page 10: ...wood tile or concrete surfaces or the walls are made of logs the heater power needs to be increased For every uninsulated square metre the heater power need increases by the same amount as if increas...

Page 11: ...11 Installation and Operating Instructions Ahti Ukko Heating control Indicator Heater on 7 Wiring diagram...

Page 12: ...ing up after two hours When the power has been switched on the heater will remain on for a maximum of 4 hours After that the power will be switched off automatically You can switch the power off soone...

Page 13: ...n If necessary contact the dealer or manufacturer Warnings Due to a risk of fire do not use the sauna to dry clothes or laundry Exercise caution with a hot heater since the heater stones and metal par...

Page 14: ...l Small pebbles or pieces may come off the soapstones used in the heater As this is not a failure of the organic material but a natural feature that cannot be predicted at the time of manufacturing th...

Page 15: ...15 Installation and Operating Instructions Ahti Ukko 10 Heater maintenance history Date Procedure...

Page 16: ...Technical support info mondex fi Premec Oy Kettukallionkatu 4 84100 Ylivieska Finland info mondex fi www mondex fi...

Reviews: