5)  When setting up a single subwoofer, it is not 

important to place the subwoofer exactly in 
the middle between the stereo speakers as 
it will not be possible to precisely locate the 
very low frequencies reproduced by the sub-
woofer . However, do not place it too close 
to walls or in corners; this would distort the 
frequency response .

Prior to making connections or changing any 
existing connections, switch off the amplifier 
module and the units to be connected .

4.1 Connecting a signal source

Connect a signal source with line level (e . g . out-
put of a mixer or preamplifier) to the RCA jacks 
LINE IN (5) . When connecting a stereo signal 
source, a mono signal is internally created . It 
is also possible to connect the jack L / LFE to an 
LFE output . In multi-channel systems for cin-
ema applications, e . g . “5 .1”, the LFE channel 
is used for low-frequency special effects (“Low 
Frequency Effect” or “Low Frequency Enhance-
ment”) .

Alternatively, connect the screw terminals 

HIGH LEVEL INPUT (7) to the speaker outputs 
of a power amplifier [in parallel to the speakers 
connected there] . Connect the left channel to 
the terminal pair “L”, connect the right channel 
to “R” . Observe the correct polarity: Always con-
nect the positive pole (marked core of speaker 
cable) to the red terminal .

Caution!

• 

Only connect amplifiers with a maximum out-
put voltage of 2 × 20 V (corresponding to an 
output power of 2 × 100 W at 4 Ω or 2 × 50 W 
at 8 Ω) to these terminals .

• 

When connecting the screw terminals, make 
sure that the cable ends are only stripped for 
the length required and that no bare wires 
protrude (hazard of contact and short circuit) .

4.2 Signal output

At the RCA jacks LINE OUT (6), the input signal 
is available for being routed to another amplifier 
or active speaker system . The position of the 
controls LEVEL (2), CUT OFF (3) and PHASE (4) 
has no effect on this output signal .

4.3 Power supply

Connect the mains cable provided to the 
mains jack (9) and the plug to a mains socket 
(230 V/ 50 Hz) .

5  Operation

CAUTION

Never adjust the speaker system 
to a very high volume . Permanent 
high volumes may damage your 
hearing! Your ear will get accus-
tomed to high volumes which do 
not seem to be that high after 
some time . Therefore, do not fur-
ther increase a high volume after 
getting used to it .

Note:

 To prevent switching noise, always switch on 

the signal source connected before switching on the 
amplifier module . After use, switch off the amplifier 
module first .

1) Before switching on for the first time, set the 

LEVEL control (2) to minimum (left stop) for 
the time being . Switch on the amplifier with 
the POWER switch (8) . As long as no signal 
is applied, the module is on standby to save 
power and the LED STANDBY/POWER (1) 
shows red . As soon as a signal is applied, the 
power amplifier is switched on and the LED 
shows green .

2)  Via the existing speaker system, reproduce 

music, for example, and add the desired low 
bass part with the LEVEL control (2) . Only 
turn up the control to such an extent that the 
sound reproduced is not distorted .

3)  Use the control CUT OFF (3) to set the upper 

cut-off frequency of the subwoofer in such 

Summary of Contents for 32.0800

Page 1: ...RONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS ELECTRONICS FOR SPECIALISTS BEDIENUNGSANLEITUNG INSTRUCTION MANUAL SAM 500D Bestell Nr Order No 32 0800 Verst rker Einbaumodul f r Subwoofer Amplifie...

Page 2: ......

Page 3: ...n Gebrauch 5 3 Einsatzm glichkeiten 5 4 Montage und Anschluss 5 4 1 Signalquelle anschlie en 6 4 2 Signalausgang 6 4 3 Stromversorgung 6 5 Bedienung 6 6 Technische Daten 7 English 1 Operating Elements...

Page 4: ...le operating temperature range 0 40 C This product is n o t i n t e n d e d for use other than stated SAM 500D DIGITAL SUBWOOFER MODULE MONACOR INTERNATIONAL ZUM FALSCH 36 28307 BREMEN GERMANY 230V 50...

Page 5: ...dient dann als tieffrequente Erg nzung bestehender Lautsprecheranlagen wenn eine berzeugende Basswiedergabe gefordert ist Das Modul verf gt ber ein Tiefpassfilter mit einer einstellbaren Grenzfrequenz...

Page 6: ...gsleistung von 2 100W an 4 oder 2 50W an 8 an Achten Sie beim Anschluss der Schraubklem men darauf dass die Kabelenden nicht zu weit abisoliert sind und keine blanken Dr hte herausragen Ber hrungs und...

Page 7: ...chtet rot Bei l nge ren Betriebspausen das Verst rkermodul mit dem Schalter POWER ausschalten 6 Technische Daten Ausgangsleistung an 4 8 Sinusleistung 500W 250W Spitzenleistung 700W 350W Frequenzberei...

Page 8: ...fuse to qualified service personnel Protect the unit against moisture and heat Permissible operating temperature range 0 40 C This product is n o t i n t e n d e d for use other than stated SAM 500D D...

Page 9: ...complement existing speaker systems with low frequencies when a convincing bass reproduction is required The module is provided with a low pass filter with adjustable cut off frequency 40 200Hz and a...

Page 10: ...ting the screw terminals make sure that the cable ends are only stripped for the length required and that no bare wires protrude hazard of contact and short circuit 4 2 Signal output At the RCA jacks...

Page 11: ...on standby The LED STANDBY POWER 1 shows red If the amplifier module is not in use for longer intervals switch off the ampli fier module with the POWER switch 6 Specifications Amplifier power at 4 8 R...

Page 12: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1374 99 02 02 2017...