14
Cable strappings’ installation:
• The strappings are fixed on the floor with staples or screws (when the floor is made of plywood or wood)
or with a hot glue gun;
• The strappings must follow the outline drawn on the room layout (section 7.2);
• If the lacing distance between two strappings is over 0.625 m (2 ft.), it is necessary to place an intermediate
strapping to maintain the cable in position during the pouring of self-leveller, this strapping is installed at the
end, after the lacing of the cable;
• The cable can be installed under the ceramic tile of a shower or other wet surfaces, the strappings and the
heating cable must be glued under the wateproofing membrane and not stapled, staples could damage
the waterproofing membrane (the UL listing for this product does not cover use in wet locations in the
United States).
on plywood
on concrete slab
Figure 7