molex Brad IO-Link M12 User Manual Download Page 1

 

Brad

®

                                                                                    

 i 

  

 IP67 IO-Link Digital Hubs 

User’s Manual 

 

IO-Link M12 Digital Hubs  

 

 

 

 
Brad

®

 from Molex 

 

 

 

Version 1.2 

October 04

th

, 2018

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for Brad IO-Link M12

Page 1: ...Brad i IP67 IO Link Digital Hubs User s Manual IO Link M12 Digital Hubs Brad from Molex Version 1 2 October 04th 2018...

Page 2: ...D Ratings update 1 1 October 04th 2017 OL Adding TEDIO 8B4P 808 1 1 2 Although every effort has been made to ensure the accuracy of this document all information is subject to change without notice Mo...

Page 3: ...or damages which occur in shipment to or from Buyer or due to improper installation maintenance misuse neglect or any cause other than ordinary commercial or industrial applications In particular Bra...

Page 4: ...tem description 10 IO Link Power supply connector 11 IO Ports 13 Functional Earth Connection 15 3 Technical Data 16 Dimensions 16 Mechanical and Environmental Data 17 IO Link Power Supply Electrical D...

Page 5: ...ent Preventive and corrective maintenance Persons who modify Brad products hardware and software configuration and install the product updates supplied by the manufacturer These persons must o be trai...

Page 6: ...ated systems power supply cables sensors etc already carry a protection index equivalent to IP67 or higher Always connect the Brad product to the functional earth FE in compliance with existing standa...

Page 7: ...en replacing parts or components only use factory approved parts In all cases before servicing a Brad product disconnect the power supply from the device unplug the power cord or open the power cut ou...

Page 8: ...includes advanced diagnostic features Each hub embeds visible LEDs to provide maintenance personnel the ability to easily determine power I O and IO Link status IO Link digital hubs main features Digi...

Page 9: ...ions SAP No Material No Description 112103 5000 TEDIO 8D0P 808 IO Link Digital Hub 16x inputs 112103 5001 TEDIO 8B4P 808 IO Link Digital Hub 12x inputs 4x outputs 112103 5002 TEDIO 8B4P 808 1 IO Link...

Page 10: ...bs Physical System description IO Link connector Mounting screw Functional Earth FE I O Connectors Plastic label Port 0 Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Shield Plate Mounting hole 3 LE...

Page 11: ...08 TEDIO 8D0P 808 except if additional Sensor Power software configuration dependent is required 3 Common L UL 0V 4 C Q IO Link data transmission cable 5 Shell FE Functional Earth LEDs 6 Bi color red...

Page 12: ...IO Link communication IO Link Master power supply The Molex IO Link IP67 master modules TCIEP 888P D1U for PROFINET and TCIEI 888P DYU TCIEI 888P D1U for EtherNet IP provide 1 6A on Pin1 L of the IO L...

Page 13: ...ital Input DI Even number 5 Not connected 6 FE Functional Earth LEDs 7 Bi color red green LED for even channel indicator Pin4 8 Bi color red green LED for odd channel indicator Pin2 Input Output Pin I...

Page 14: ...ot connected 6 FE Functional Earth LEDs 7 Bi color red green LED for even channel indicator Pin4 8 Bi color red green LED for odd channel indicator Pin2 Note M12 accessories cordsets plugs connected t...

Page 15: ...State Ox Fixed Green DO is energized Fixed Red DO when energized and shorted to ground DO when not energized and shorted to 24V DO when overload detected DO when energized and UL is over voltage UL 3...

Page 16: ...Brad 16 IP67 IO Link Digital Hubs 3 Technical Data Dimensions All dimensions are in millimeters...

Page 17: ...oHS RoHS China REACH 1 Only when all necessary waterproof connectors and caps have been installed IO Link Power Supply Electrical Data Hub versions TEDIO 8D0P 808 TEDIO 8B4P 808 TEDIO 8B4P 808 1 IO Li...

Page 18: ...ed TEDIO 8B4P 808 1 Max draw current in total 800mA if input only TEDIO 8D0P 808 2 8 A if input output combined TEDIO 8B4P 808 2 8 A if input output combined TEDIO 8B4P 808 1 Sensors draw current from...

Page 19: ...Undervoltage x L or UL 1 Undervoltage detected 0 No default OVx Overvoltage x L or UL 1 Overvoltage detected 0 No default OCx Overcurrent x L or UL 1 Overcurrent detected 0 No default GST Global Statu...

Page 20: ...inputs 4 outputs DOx Digital Output data x Channel number 1 output energized 0 output not energized TEDIO 8B4P 808 1 12 inputs 4 outputs grounded DOx Digital Output data x Channel number 1 output ene...

Page 21: ...IO Link hubs require a description file also called IODD file that has to be imported in the library of the IO Link master configuration tool ex TIA Portal or Step7 The IODD file can also be downloade...

Page 22: ...a from Device to Master Value 0x82 Byte unit no SIO 3 bytes 0x07 ProcessDataOut R Number and structure of output data Process Data from Master to Device TEDIO 8B4P 808 01 Value 0x82 Byte unit 3 bytes...

Page 23: ...uts TEDIO 8B4P 808 1 HarshIO IO Link Digital Hub 12x inputs 4x outputs Grounded 0x15 Serial Number R 0x16 H W Revision R 1 0 0x17 F W Revision R 1 0 0x18 Application Specific Tag R W See Application S...

Page 24: ...See Sensor Power Status R Read access only R W Read Write access Fail State Parameter The Fail State parameter defines the predetermined state of each output in case of communication failure The Fail...

Page 25: ...n SSV bit 1 and if UL is below 8V then UVUL and GST will not be set to 1 Note The behavior of the I O status LED is not affected by this parameter The status of the I O LED is only dependent of the vo...

Page 26: ...on is set 0 Remove current limit default 1 Limit current to 200 mA IO Link compatible UCM UL Current limit Mode If UL current limit is reached 3 5A as example in case of short circuits the overcurrent...

Page 27: ...0ms Name UL Voltage Index Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0x0047 0 0 0 0 0 0 0 Voltage value is tenth of volts Example 178 17 8V Output Status This parameter returns an indication of current...

Page 28: ...s available current overload detected 100mA 0 No status available Default ISDU Error type Errors Error Codes Description 0x8000 Device application error no details 0x8011 Index not available 0x8012 Su...

Page 29: ...at may have caused the problem Note Your product identification is located on the side of the device Web Site To assist users in using the products Molex provides technical information on its web site...