Crimp Force Monitor
Doc. No: TM-638007950
Release Date: 03-21-13
UNCONTROLLED COPY
Page 13 of 21
Revision: A
Revision Date: 03-21-13
3.5.2 Press Inhibit
The crimp force monitor can be programmed to inhibit the press immediately after a bad crimp. This
functionality is associated with the operation of the FAIL or SUSPECT output. Several methods are available
to reset the machine allowing the operator to continue production. With the reset method set to
Keypad,
the
operator will be required to press a button on the keypad continue. Alternatively, if more control is required,
the INPUT option requires that the digital input to be activated before production can continue. This option
allows for external devices such as a key switch.