Crimp Force Monitor
Doc. No: TM-638007950
Release Date: 03-21-13
UNCONTROLLED COPY
Page 12 of 21
Revision: A
Revision Date: 03-21-13
If the signature error exceeds either the outline box then the fail condition is annunciated in Red on the screen
as shown below.
3.4.2
Counter Screen
The
Counter Screen
totals the number of “Pass”, “
Suspect
” and “
Fail
” parts while automatically calculating
the scrap rate.
To clear the production counters, press enter while viewing (password may need to be entered depending on
settings)
3.5 Operator Interaction
The crimp force monitor includes several special features to help control access and limit uncontrolled
adjustment.
3.5.1 Password Access
Passwords can be optionally activated to control access to the tolerances and analysis regions and setup
menus.
The crimp force monitor utilizes 2 user accounts – “
Operator
” and “
Supervisor
”, each of which have a
unique 4 number password and access permissions.
The Passwords can be changed at any time by first entering the correct password and then entering the new
password.
Suspect Fail -ve
Gross Fail -ve