background image

 © 2021 Mold-Masters (2007) Limited. All Rights Reserved

Quick Guide for Tempmaster™ M1 

Plus Controller

 

Refer to the M1P Controller User Manual for full instructions and safety information.

Create a New Tool

1.  Choose [

Menu

] to open the ToolStore page.

2.  Choose a blank tool slot then choose [

Detect

].

3.  Enter system password.
4.  Type in a new name for the tool.
5.  Choose [

Enter

].

Configure Control Cards

1. 

Choose the first zone to be configured.

2. 

Choose the last zone to be configured.

3.  Choose [

Range

] to include all zones in between.

4.  Choose [

Set

] to see the Configure Card Slot menu.

5. 

Choose zone type: manifold, spear, monitor, special or not used.

6.  Choose header color.
7.  Choose [

OK

].

8. 

Repeat steps 1 through 4 until all zones are configured.

Note

: zones populate with default values which can be accepted or 

changed.

Configure Tool Parameters

1. 

Choose zones of the same type.

2.  Choose parameter.
3.  Choose [

Set

].

4. 

Set value.

5.  Choose [

Enter

].

Note

: see User Manual for full listing and description of tool 

parameters.

Configure Controller Parameters

1.  Choose [

Config

] to view the global parameters.

2. 

To view the global parameters and their current settings, choose 

[

List

].

3. 

Choose setting and required option / function.

4.  Choose [

OK

] to keep the changes or choose [

Cancel

] to leave 

without making changes.

Note

: see User Manual for full listing and description of global 

parameters.

Configure the Controller

Main Screens and Menus

Main Screens and Menus
Configure the Controller

Create a New Tool 

Configure Control Cards

 

Configure Tool Parameters

 

Configure Controller Parameters

 

Configure Zone Settings

 

Set Probe and Manifold Temperatures

 

Save to the Toolbank

Operate the Controller

Startup Procedure

 

Change Or Set Zone Temperatures

 

Change Modes - Individual Zones

 

Change Modes - Multiple Zones

 

Check Zone Performance

 

Shutdown Procedure

Global Support

Main Page

Functions:

• 

Monitor - observe zone 

condition

• 

Control - choose mode

• 

Navigation - [

Menu

]  

button opens the 

Navigation screen 

ToolStore Page

Description:

List of tools with names and 

saved settings

Utilities Page

Gives access to:

• 

Exit

• 

Config

• 

Export

• 

Quad IO

Setup Page

Description:

User can configure and 

alter global and specific tool 

parameters.

Graph Page

Description:

Displays historical record 

of the last 30 minutes of 

operation

Reviews: