Table 5-4 Tool Parameters
Function
Description
Setting Limits
Alarms Active
Offers a selection table which allows you to
decide how any of the following alarm conditions
should affect the system:
• High Temperature Alarm
• Low Temperature Alarm
• Zone Alarm
• Power Alarm
• Reynolds Number Alarm
Option for alarm actions:
Console
– displays the alarm
condition in that one panel and
the Status panel.
Beacon
– extends the alarm
to activate an attached Alarm
Beacon and Sounder.
Mold Protect
– puts the
console into Stop mode. All
zone heaters will cool down.
Injection Disable
– sends out
a shutdown signal from the IO
card, which may be externally
configured to stop the molding
machine.
Alarm Power
Generates an alarm if any average power level,
which is measured over the previous eight
minutes, exceeds this setting.
This defaults to 100% or to
Off. Maximum power can be
sutained without generating any
power alarm.
Alias
Input for alternative zone names.
Has an auto-increment number
facility.
Analogue
Sensor Type
Configures analogue inputs to match analogue
flow sensors.
Boost
(temperature)
Sets the increase in temperature when Boost is
selected.
The maximum Boost value
is 250°C or 450°F above the
normal set temperature.
Display
Group
Chooses groups of zones to display on separate
main page.
By default, all zones are in group one but
selected zones can be allocated to subsequent
groups.
Zones that need not be shown on the main page
can be put in display group zero.
There is a limit of six display
groups.
Master Zone
Chooses a Master zone for any group of sub-
zones.
Do not choose until all zones
have been configured to correct
types.
Maximum
Power Setting
Sets the highest permitted power level for the
zone(s).
The highest Maximum Power
Setting is 100% power.
Maximum
Setpoint
Setting
Sets the highest permitted setpoint for the
zone(s).
The highest Maximum Setpoint
temperature is 450°C or 842°F.
Minimum
Setpoint
Setting
Sets the lowest permitted setpoint for the
zone(s).
The lowest Minimum Setpoint
temperature is 0°C or 0°F.
5.11 Tool Parameters
5-11
SETUP
© 2021 Mold-Masters (2007) Limited. All Rights Reserved.
M1 Plus Controller User Manual