3.14 Lift the E-Multi Injection Unit
WARNING
When doing any work on the machine that requires lifting the machine,
connect all lifting devices and support the machine using a crane of
adequate capacity before commencing work. Failure to support the
machine can result in severe injury or death.
Never use the motor as a lifting point.
Never use an E-Multi attached to the mold as a lifting point.
Figure 3-5 Do not use the motor as a lifting point
Table 3-10 E-Multi Injection Unit Lifting Kits
EM1 / EM2
2 x 16 mm (5/8 in.) bow shackles
2 x 1220 mm (48 in.) slings
EM3
2 x 25 mm (1 in.) bow shackles
2 x 1830 mm (72 in.) slings
3.14.1 Prior to Lifting the E-Multi Injection Unit
1. Choose lift equipment that is rated for the prescribed load. See equipment
tag.
2.
Define the
load path:
the path and orientation the item will move in while
it is being lifted, and the location and orientation where it will be set down.
3. Use recommended attachment points only. See Section 3.15.
4. Identify and avoid potential
pinch points:
where an individual or a
component of the lifting equipment or load may be caught between two
surfaces.
5. Secure and balance the load in the chain or lifting device before it is lifted
more than a few inches.
6. Minimize swinging by bringing the hook over the load appropriately.
7. Move powered hoists slowly into engagements with loads.
3-21
SAFETY
E-Multi User Manual