5-3
ASSEMBLY
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
Dura+ User Manual
5.3 Assembly of Gate Seals to Nozzle
1. Apply anti-seize compound to all threaded interfaces.
2. Ensure all sealing surfaces are clean and dry.
3. Install gate seal and liner.
4.
Torque to specified values. Refer to the General Assembly drawing for
torque values.
5. Heat nozzle to processing temperature and re-torque seal.