Dura+ User Manual
MAINTENANCE PROCEDURES
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
11.10 Nozzle Thermocouple Removal
NOTE
Removing thermocouples will damage them and is not recommended
unless replacing a damaged thermocouple with a replacement one.
1. Remove the thermocouple from the electrical box and wire channels.
2. Remove the nozzle from the manifold plate.
3. Remove the thermocouple retaining clips.
4. Remove the thermocouple.
11.11 Torque Settings
11.11.1 Gate Seal Torque Settings
CAUTION
Gate seals are torqued at ambient (room) temperature at
Mold-Masters
. Please torque each seal at processing temperature to the
torque value specified to prevent material leakage from the gate seal.
CAUTION
Table 11-2 Gate Seal Torque Settings
Nozzle
Nm
ft-lb
Deci
34-38
25-28
Hecto
47-54
35-40
Mega
57-65
42-48