SITE REQUIREMENTS

NOTES

1.

Recommended for all new installations.

2.

Use maximum internal diameter for the main line when preparing any new installation.

Electrical

V3 & V5

V7

2V3 & 2V3CT

2V5 & 2V5CT

2V7

3V5

4V5

Master Controller

Voltage Rating Volts AC 

All pumps 

220 Volts Single Phase AC, 50/60 Hz

120 / 220

Voltage Minimum/Maximum

198/242 Volts AC All pumps

108/132 V

olts AC or 

1

98/242 V

olts AC 

Wire Size AWG Minimum 

Gauge

#12 AWG  

(Qty 1)

#10 AWG  

(Qty 1)

#12 AWG 

(Qty 2) 

#12 AWG 

(Qty 2) 

#10 AWG 

(Qty 2) 

#12 AWG 

(Qty 3)

#12 AWG 

(Qty 4)

#14 AWG

Minimum Circuit Breaker 

Rating

20A

30A

20A (Qty 2) 

20A (Qty 2) 

30A (Qty 2)

20A (Qty 3)

20A (Qty 4)

15A

Incoming Power

Hard wire Connection  (Each pump is supplied a 6 foot BX cable)

NEMA 5-15R for 120V 

NEMA 6-15R for 220V

(Supplied 10-ft. line cord)

Remote

(Low Voltage Wiring)

#18 AWG  (Qty 4) Wire Connection between the MMC and the Remote Switch Panel . 

Plumbing

V3

V5

V7

2V3 & 2V3CT

2V5 & 2V5CT

2V7

3V5

4V5

Exhaust Vent Pipe Using Heat Exchanger

2” PVC 

 Sch. 40

2” PVC 

Sch. 40

2” PVC 

Sch. 40

One 3” or two 

2” PVC Sch. 40

One 3” or two 

2” PVC Sch. 40

One 3” or two 

2” PVC Sch. 40

One 4” or three 2” 

PVC Sch. 40

Two 3” or four 

2” PVC Sch. 40

Exhaust Vent Pipe Not Using Heat 

Exchanger (See note 1)

2” Metal Pipe

2” Metal Pipe

2” Metal Pipe

One 3” or two 

2” Metal Pipe

One 3” or two

2” Metal Pipe

One 3” or two

2” Metal Pipe

One 4” or three 

2” Metal Pipe

Two 3” or four 

2” Metal Pipe

Minimum Suction Line Pipe

1” PVC 

Sch. 40

½

”  PVC 

Sch. 40

2” PVC 

Sch. 40

½

” PVC 

Sch. 40

2” PVC 

Sch. 40

3” PVC 

Sch. 40

3” PVC 

Sch. 40

3” PVC 

Sch. 40

Maximum Suction Line Pipe (See note 2)

½

” PVC  

Sch. 40

2” PVC 

Sch. 40

½

” PVC 

Sch. 40

2” PVC 

Sch. 40

½

” PVC 

Sch. 40

4” PVC 

Sch. 40

4” PVC 

Sch. 40

4” PVC 

Sch. 40

Riser Pipe

½

” PVC 

Sch. 40

½

” PVC 

Sch. 40

½

” PVC 

Sch. 40

½

” PVC 

Sch. 40

½

” PVC 

Sch. 40

½

” PVC 

Sch. 40

½

” PVC 

Sch. 40

½

” PVC 

Sch. 40

Vacuum Line Termination

½

” FNPT

½

” FNPT

2” FNPT

2” FNPT

2” FNPT

2” FNPT

2” FNPT

2” FNPT

Branch Line Pipe

Size requirement of Branch piping differs by the number of operatories being serviced.

Up to two operatories use 1" PVC Schedule 40.

Three to six operatories use 1 

½

” PVC Schedule 40.

More that six operatories use 2" PVC Schedule 40

Drain Line Pipe

½

” PVC Schedule 40

Wash-Out Water Line

½

” FNPT Shut-off Valve

Summary of Contents for V3

Page 1: ..._____________________ Phone __________________________________________________ Dealer __________________________________________________ Dealer Address __________________________________________________ All installations must conform to local codes All pumps comply with NFPA 99C level 3 requirements System being installed AS CHECKED q V3 q V5 q V7 q 2V3 q 2V3CT q 2V5 q 2V5CT q 2V7 q 3V5 q 4V5 ...

Page 2: ...aust to Outside Vent V3 V5 or V7 Vacuum Pump Heat Exchanger Gate Valve Check Valve Sewer Drain MT10 Separator Tank Gas Typical MOJAVE System Installation Liquids Solids System Components V3 V5 V7 2V3 2V3CT 2V5 2V5CT 2V7 3V5 4V5 V3 Pump Assembly 1 0 0 2 2 0 0 0 0 0 V5 Pump Assembly 0 1 0 0 0 2 2 0 3 4 V7 Pump Assembly 0 0 1 0 0 0 0 2 0 0 MT10 MT12 Tank Assembly 1 1 1 1 0 1 0 0 0 0 CT20 CT22 Tank As...

Page 3: ... in 28 cm 13 5 in 34 cm 3 in 8 cm V3 V5 and V7 Vacuum Pump Dimensions 17 in 43 cm 25 in 64 cm 21 in 53 cm 17 5 in 44 cm 2V3 or 2V5 System Installation Recommended Stacked Pumps with Tank on Side 33 in 84 cm 34 in 86 cm V3 V5 and V7 System Dimensions 23 in 58 cm 50 in 127 cm 2V7 2V3CT or 2V5CT System Installation Recommended Stacked Pumps with CT20 CT22 Tank on Side 34 in 86 cm 50 in 127 cm MT10 MT...

Page 4: ... Height from Riser Trap to Main Line OVERHEAD INSTALLATION Alternate system installation layout should be used only when unable to use the sub floor plumbing layout Ceiling Junction Box See Note 2 1 2 Inch Diameter Riser Minimum Slope 1 4 inch per 10 Feet Main Line Riser for connection to tank input See Note 1 MAIN LINE See Notes 2 3 4 Junction Box See Note 2 MAIN LINE See Notes 2 3 4 5 CONNECTOR ...

Page 5: ...ng water pressure between 20 and 100 psi for daily tank washout Valve location must be no more than 10 feet from the tank installation to allow connection of supplied 10 foot 3 8 inch Poly tubing to the tank washout port Provisions for backflow prevention may be required Check local code requirements E MASTER CONTROLLER ELECTRIC OUTLET Master Controller requires a dedicated standalone 120V 5 AMP o...

Page 6: ... PVC Sch 40 2 PVC Sch 40 One 3 or two 2 PVC Sch 40 One 3 or two 2 PVC Sch 40 One 3 or two 2 PVC Sch 40 One 4 or three 2 PVC Sch 40 Two 3 or four 2 PVC Sch 40 Exhaust Vent Pipe Not Using Heat Exchanger See note 1 2 Metal Pipe 2 Metal Pipe 2 Metal Pipe One 3 or two 2 Metal Pipe One 3 or two 2 Metal Pipe One 3 or two 2 Metal Pipe One 4 or three 2 Metal Pipe Two 3 or four 2 Metal Pipe Minimum Suction ...

Page 7: ...rizontal to Floor 3 PVC or Copper Clean out Plug Used with P N MIK4 Supplied by Plumber Air F l o w 2 PVC or Copper Tubing for Tank Hose Supplied by Plumber Check Valve Side View CT20 TANK INLET CONNECTION DETAIL 6 inch Riser Customer Supplied Tee Connector 3 4 FNPT 2 Flexible Coupling Connector 1 4 inch Vacuum Sample Port to Master Controller Reducing Bushing Swivel Elbow 2 Pipe for connection to...

Page 8: ...ush Elbow 35 18 Exhaust Vent Protection If the exhaust piping is venting to the outside of the building precautions must be taken to protect the equipment room from weather elements and animal intrusion This can be accomplished by using one of the three methods shown on the right Wall Mounted Outside Vent Protection Shroud Screen Roof Mounted Outside Vent Protection Shroud Screen Screen Exhaust Ve...