background image

17

ENG

  8-D24-53-031.12     ESK 180-110  

Maintenance 

Danger  of  injuries! 

Do  not  forget  to 

secure the Designer grille roll!

3. Clean the Heat Exchanger

Remove the Designer Grille. To clean the hand-accessible area of the heat 
exchanger, we recommend a dry dust cloth or broom. Hard to reach places 
can be cleaned with a vacuum cleaner equipped with a soft brush nozzle or 
a soft brush. Replace the filter, if needed, and the Designer Grille.
      

Manual storage

Please give this manual to the later users as a document for revision in the 
scope of commissioning and hand over of the equipment, because it inclu-
des important notes on maintenance and care.

Technical Support

Technical support

Mo to Thu:  

 

7:30 to 17:00 Uhr  

Fr:  

  7:30 to 15:00 Uhr  

Service-Telephone:   +49 (0) 53 41  8475 - 470 
Service-Fax: 

  +49 (0) 53 41  8475 - 999 

E-Mail: 

  [email protected] 

Mailing Address  

Möhlenhoff Wärmetechnik GmbH
Techniscal Support
Museumstraße 54a
DE 38229 Salzgitter
Germany

All  trades  participating  on  the  installation,  connection  and  com-
missioning of the ESK need information from this manual in order 
to perform their work. Please ensure that the manual is disclosed 
correspondingly after the termination of the individual parts of the 
work.

Copyright

This manual is protected by copyright. All rights reserved. It may not be 
copied, reproduced, abbreviated or transmitted, neither in whole nor in 
parts, in any form, neither mechanically nor electronically, without the pre-
vious consent of the manufacturer. The basing information was evaluated 
thoroughly and arranged to the best knowledge. 

    © Copyright 2009

Declaration of Conformity

The manufacturer declares in sole responsibility that the product 
ESK  complies  with  all  applicable  requirements  of  the  guidelines 

2004/108/EG and 2006/95/EG.
The following standards were used for the assessment:
• EN 60335-1:2002
• EN 60335-2-30:2003+A1:2004

Summary of Contents for ESK 180-110

Page 1: ...e 4 Product Description 4 Areas of Application 4 Dimensions 5 Technical Data 5 Identification Label 5 Preconditions 6 Expert Knowledge 6 Site of Installation 6 Installation Situation 6 Operating Mode 7 Convection Principle 7 Installation 8 Installation Preparation 8 Height Adjustment 8 Free Full load Capacity 8 Installation Preparation 9 Protection Cover 9 System Extensions 10 Electrical Connectio...

Page 2: ...Produktübersicht 2 Lieferumfang 2 Standardkomponenten 2 Optionale Komponenten 2 Geräteübersicht 4 Produktinformationen 5 Bestimmungsgemäße Verwendung 5 Produktbeschreibung 5 Einsatzbereiche 5 Abmessungen 6 Technische Daten 6 Typenschild 6 Konformitätszeichen 6 Voraussetzungen 7 Fachkenntnisse 7 Montageort 7 Funktionsweise 8 Konvektionsprinzip 8 Montage 9 Montagevorbereitung 9 Höhenjustierung 9 Fre...

Page 3: ...oduct Overview Overview Temperature switch and safety fuse Heat exchanger Height Adjustment Blocks Endplate Control box ELS 1000 System trough Air channeling bar System bulkhead Electrical heating rod 1 2 3 4 5 6 7 8 9 4 1 2 3 5 6 7 8 2 9 ...

Page 4: ...t be performed as fixed connection Height adaptation is possible by means of adjustment blocks The convector is covered with a covering grille which can be removed by hand the designer roll grille The desi gner roll grille is fixed with roll grille protectors Product Description The Electric System Convector ESK is used when the architectural situation requires an economical and comfortable room h...

Page 5: ... switch Integrated into heat exchanger for protection against defective thermostats or accidental covering of unit Fuse up to 3 x 6 3 AT circuit protection in connection boxes depending on variant Protection class I Protection type IP 20 CE rating EN 60335 Convector length see identification label Electric plug terminal for max cable width 2 5 mm Window view right left on request Once the fuse is ...

Page 6: ...rately Expert Knowledge Preconditions Installation Situation 3 Connection line 2 Border acoustic insulation 1 Continuously elastic border strips Screed and flooring particularly hardwood flooring can compress the trough of the under floor convector due to the thermal proper ties We recommend the planning and use of proper insulation duri ng the installation phase The electrical connection is norma...

Page 7: ...7 ENG 8 D24 53 031 12 ESK 180 110 1 cooled air cold air gradient 2 warmed air for cold air barrier and room heating Convection Principle Natural Convection Heating 1 2 ...

Page 8: ...for ESK on the fan side are only available with a distance of 500 mm The following applies for free complete step on ability in case of exterior adjustment blocks without support capacity up to 130 kg m if distance between support max 500 mm capacity up to 180 kg m if distance between support max 400 mm kg 130 A 500 mm kg 180 A 400 mm Top view Outer Adjustment Blocks with Feet JBA 8 80 Inner Adjus...

Page 9: ...paration To prevent the movement or warping of the ESK during the use of wet or hot screed we recommend that the unit be anchored in at least 4 points to the unfinished floor with Adjustment Blocks Protection Cover Remove the protective cover permanently only after finishing the installati on of the system convector and after finishing all building work By this you avoid contamination and damage t...

Page 10: ...e delivered ready to plug in they are also installed with system connectors Installation Electrical Connection Note for electrical connection there are 3 heating element types 220 W 500 mm length 470 W 1000 mm length 570 W 1250 mm length All ESK are equipped with the ELS 1000 for the electrical connection Through this controller the resistance and control current are in relation to the connection ...

Page 11: ...ection and circuit diagrams are given without electrical protection devices measures Installation Optional controller for temperature setback without an Alpha Thermostat Control Circuit Plan AR 2010 K2 S AR 2010 S2 S AR 2010 C2 S DS 1000 AS 1000 ...

Page 12: ...1000 Detailed Connection Plan Connecting box 1 ELS 1000 HP 1 HP 2 HP 3 ELS 1000 Heating cartridge HP 2 Heating cartridge HP 3 Heating cartridge HP 1 Thermostatic switch 2 Thermostatic switch 3 Thermostatic switch 1 Connecting box 1 PE 6 3 AT 6 3 AT PE L N N N L L PE 1 3 5 2 4 6 N L PE L L N N ...

Page 13: ...s without Alpha Thermostat Control e g DS 1000 Alpha Thermostat 230 V AC with Mounting Base AS 1000 A further wiring of the mains line via the connection terminals of the circuit boards is inadmissible We therefore recommend cor responding terminals to be provided by the customer L L N N L L N N L L N N N L PE Through connection 1 3 5 2 4 6 ...

Page 14: ... rod connectors gummed step on acoustic insulation and its exterior fixing lugs are located below the grille rod connectors Danger of jamming Always fix the designer grille roll protector above the convector fan It serves as a protection against reaching into the fan Insert the designer grille roll into the system convector trough Using an Allen key size 3 push the fixing screws to the outside and...

Page 15: ...nd comply with all current and valid national standards for electrical devices A check of all the electrical components including customer specified safety devices has been successfully performed Switch on the electric circuit for the power supply of the ESK For AR 20xx x S the desired temperature can be set Further information can be found in the user manual of the Alpha Thermostat Operation Use ...

Page 16: ...t regular cleaning in tervals during normal cleaning Wet Loosen possible grille protectors with a No 3 Allen key as shown Designer Roll Up Grille Roll the cover grill up without bending or kinking Clean in Washing Machine The DR is washing machine safe evenly up to a temperature of 60 C with normal non industrial strength dish washer cleaner After washing and drying the grille can be replaced on t...

Page 17: ...de Mailing Address Möhlenhoff Wärmetechnik GmbH Techniscal Support Museumstraße 54a DE 38229 Salzgitter Germany All trades participating on the installation connection and com missioning of the ESK need information from this manual in order to perform their work Please ensure that the manual is disclosed correspondingly after the termination of the individual parts of the work Copyright This manua...

Page 18: ...18 ENG ...

Page 19: ...19 ENG 8 D24 53 031 12 ESK 180 110 ...

Page 20: ......

Reviews: