background image

MT620J

MODELS 2290, 2291, 2600, 2700, 5401, 62600, 62700, 72615, 72700

and MODEL SERIES T471, T473, T555, T666, T777 & T888

INSTALLATION INSTRUCTIONS

THESE INSTRUCTIONS MUST BE

LEFT WITH HOMEOWNER

TUB AND SHOWER VALVES

Measurements

These are shown in the drawings.

The depth measurement is critical.  Use

the front face of the plaster ground as a reference point for the finished

wall position, including tile (2-1/16" [52mm]). 

 The center line of the supply

and discharge piping should be a maximum of 2-3/16" (56mm) and a minimum

of 1-7/16" (37mm) behind the finished wall surface.

Available with three or four port castings, with and without stops.

Connections are either 1/2 inch I.P.S. pipe or 1/2 inch copper sweat connections.

If the Moen Slip Fit spout is used, a 1/2 inch copper drop and lookout may be used.

CAUTION:

Always turn water off before disassembling the valve.  Open valve handle to

alleviate  water  pressure  to  insure  that  complete  water  shut-off  has  been

accomplished.

Before turning water on during either rough-in or trim-out, make sure that cartridge retainer clip is in place.  The

cartridge and retainer clip were properly installed and tested before leaving the factory.  Although it is unlikely, it is

nevertheless possible that through the handling of the valve by any number of persons the retainer clip may not be

properly installed.  This should be carefully checked at time of rough-in and trim-out.  If the retainer clip is not properly

installed, water pressure could force the cartridge out of the casting.  Personal injury or water damage to the

premises could result.

HANDLE

COVER

HANDLE

KNOB

WASHER

HANDLE

SCREW

HANDLE

LEVER

HANDLE ASSEMBLY

ADJUSTABLE

TEMPERATURE

LIMIT STOP

ESCUTCHEON

PLASTER

GROUND

CAUTION

USE 1/2"

IRON PIPE

SIZE

MINIMUM

OR 1/2"

TUBING.

SUPPLY

SUPPLY

45"

(1143mm)

48"

(1219mm)

1-1/4"

(32mm)

6' 6"

(1981mm)

32"

(813mm)

FINISHED WALL

LINE

2-1/16"

(52mm)

2-1/16"

(52mm)

TUB FILLER

OR SHOWER

TUB/SHOWER

COMBINATION

FLOOR

15/16"

(24mm)

®

CLIP

EAR

UP

IMPORTANT: SEE FLUSHING

INSTRUCTIONS PAGE 2

Reviews: