3.

Hot/Cold Temperature Indicator Installation (OPTIONAL)

If the temperature indicators are desired on your faucet,
installation is as follows:

a. Remove the handle hub 

(9)

from the lever or knob handle 

(2 or 4)

by grasping the handle hub in one hand and separating the handle
from the handle hub with the other hand.

b. Install the RED (HOT) temperature indicator onto a handle

assembly by aligning the indicator slots with the chassis 

(5)

tabs,

then sliding the temperature indicator over the chassis until it
makes contact with the handle.

c. Re-assemble the handle assembly with temperature indicator into the

handle hub, being sure that the chassis tabs align with the handle
hub slots.  Push the handle hub onto the chassis until it stops.

d. Repeat the above steps for installing the BLUE (COLD)

temperature indicator onto the other handle assembly.

INSTALLATION INSTRUCTIONS

ROLL PIN

GOUPILLE CYLINDRIQUE

PASADOR CILINDRICO

PLUMBER'S PUTTY

MASTIC DE PLOMBIER

MASILLA DE PLOMERO

TOP OF FINISHED SURFACE

DESSUS DE LA SURFACE FINIE

CARA SUPERIOR DE LA SUPERFICIE ACABADA

MOUNTING SHANK
TIGE DE MONTAGE

CAÑA DE MONTAJE

16

27/32" DIA. 

MOUNTING SHANK

27/32 PO DIAM. 

DE LA QUEUE
DE MONTAGE

CAÑA DE 

DIA. 27/32" (21MM)

7/32" DRILL ROLL PIN

7/32 PO GOUPILLE DE FIXATION

ORIFICIO DE 7/32" (6MM) PARA

PASADOR CILÍNDRICO

.730 (19MM)

(FRONT)

(DEVANT)
(FRENTE)

3

2

2

CAUTION:  

Remove burrs and bevel end of shank. Failure to do so may 

result in damaged spout o-ring during spout installation.

CAUTION:  See template above for roll pin location. 

Drill a 7/32" 

hole into tub base. Install spout escutcheon 

(16)

with roll pin. 

!

!

1

1. Apply a bead of plumber’s putty (not provided) under the bottom of the

spout escutcheon (16). Using the grease packet (supplied), apply
grease to the o-ring seals of the spout mounting shank pictured above.
Place the spout escutcheon over the mounting shank and onto the
deck.  With the roll pin in place, assemble the spout (14) onto the
mounting shank by engaging the mounting shank into the spout, then
lowering the spout onto the spout escutcheon.  Install the set screw
(13) and secure the spout to the deck with a 5/32” hex wrench
(provided) by applying a slight downward pressure to the spout, and
rotating the hex wrench clockwise until the spout is firmly seated
against the spout escutcheon.
NOTE:  the aerator is pre-assembled into the spout.

2. Apply a bead of plumber’s putty (not provided) under the bottom of 

the two handle escutcheons 

(10)

.  Place handle escutcheons over each

valve body, allowing them to rest on deck.  Rotate the valve stem
extensions pictured above to the “OFF” position (clockwise for HOT
[RED] and counter-clockwise for COLD [BLUE]).

4. Position the HOT (left) handle assembly on valve pointing 180 degrees

from the spout mounting position.  Holding the handle stationary with
one hand, apply a slight downward pressure and rotate the handle hub

(9)

clockwise with the other hand (to ensure correct handle installation,

rotate the handle clockwise, then counter-clockwise.  The handle should
stop in both directions).  Taking care not to cross-thread, continue to
tighten the handle hub by hand until it is firmly seated against the
handle escutcheon.

NOTE:

The handle should stop in the “OFF” position when the handle is 

pointing away from the spout position, and full “ON” when the 
handle is pointing towards the operator.  Repeat the above step
for installing the COLD (right) handle assembly.

4

2 or 4

8

5

9

10

9

Valve Stem Extension

10

Summary of Contents for T940 Series

Page 1: ...ne telephone numbers to call TIPS FOR REMOVAL OF OLD FAUCET CAUTION Always turn water OFF before removing existing faucet or disassembling the valve Open faucet handle to relieve water pressure and en...

Page 2: ...s d arr t Bec A rateur Rosace de bec Tapa Maneral de perilla Adaptador de maneral de perilla Maneral de palanca Bastidor Arandela en onda Adaptador del maneral Indicador de temperatura Cubo del manera...

Page 3: ...er s putty not provided under the bottom of the spout escutcheon 16 Using the grease packet supplied apply grease to the o ring seals of the spout mounting shank pictured above Place the spout escutch...

Page 4: ...r warranties conditions and guarantees whether expressed or implied statutory or otherwise including without restriction those of merchantability or of fitness for use Some states provinces and nation...

Page 5: ...ous de la rosace de bec 16 Utiliser le sachet de graisse fourni et appliquer de la graisse sur les joints toriques de la tige de montage du bec illustr e ci dessus Placer la rosace de bec sur la tige...

Page 6: ...cons cutifs Les limitations ou les exclusions pr cit es ne s appliqueraient pas dans ces cas Cette garantie accorde des droits juridiques et il est possible que d autres droits soient applicables selo...

Page 7: ...chapet n del surtidor 16 Usando el paquete de grasa incluido engrase los sellos de caucho de la ca a de montaje del surtidor ilustrada arriba Coloque el chapet n sobre la ca a del surtidor y desl celo...

Page 8: ...incidentales o consiguientes y por este motivo las limitaciones citadas pueden no afectarlo a Ud Esta garant a le otorga derechos legales espec ficos y posiblemente tenga tambi n otros derechos que va...

Reviews: