background image

            

MT692C

WITHOUT STOPS

WITH STOPS

7"

7"

SHOWER

SHOWER

SUPPLY

TUB

TUB

SUPPLY

SUPPLY

2-3/4" C.C.

& I.P.S.

2-5/16" C.C.

& I.P.S.

4-13/16" C.C.

4-5/16"

NOMINAL

4-1/2"

PLASTER 

GROUND

SIZE AND

WALL

OPENING

C.C.

I.P.S.

CLAMP
SCREW

CAUTION

This  valve  is  equipped  with  the  Moen
long-life 

POSI-TEMP 

cartridge,

designed  for  smooth,  trouble-free
operation. When soldering do not heat
valve any higher than necessary to flow
the  solder.  Overheating  may  damage
the  cartridge  or  rubber  stop  valves.
Following  this  direction  will  allow  you
to  solder  without  removing  the  car-
tridge or rubber stop valves.

WARNING

:  The  cartridge  and  rubber

stop  valves  MUST  be  removed  before
either  brazing  or  resistance  (electric)
soldering.

CLIP/BARS

ORIENT THE CLIP IN THE SPOOL AND THE
CAP FINGERS AS SHOWN ABOVE.

CAP

O-RINGS

CLIP/BARS

STEM ASSEMBLY

BALANCE

SPOOL

Stop Operation

CC - This type is integral with casting, actuated by screwdriver, and require a 90° turn to
open or close.  When the screwdriver slot is vertical, the rubber stop is closed, and when
the slot is horizontal, the rubber stop is open.

IPS - This type has been added to the basic shower casting and is actuated by a screwdriv-
er. The stop is opened by rotating in a counterclockwise direction until it stops and closed
by rotating in a clockwise direction until it bottoms.

MAKE SURE ALL WATER SUPPLIES ARE OFF.

Note the word "TOP" on the casting. Install casting with the TOP facing UP. If the valve is to be
used for a shower only, plug the bottom outlet. If the valve is to be used for both a shower and
a tub, connect the top outlet to the shower and the bottom outlet to the tub. Secure all pipes
and the shower and tub drop ells. Use thread seal tape on all threads. 

Rough-In

Flushing

IMPORTANT: Before closing all wall openings, pressure test valve and complete sys-
tem using flushing instructions

Pipe chips, sand and other solids found in new and renovated plumbing can damage the sealing surfaces
of the cartridge causing a leak or cause the spool to become blocked. To avoid damage, 

DO NOT

TURN ON SUPPLY VALVES

until instructed below.

Make  sure  both  hot  and  cold  supplies  are  off

.  Rotate  the  cartridge  stem  until  the  notched  flat  points  up  to

relieve pressure and insure complete shut-off. Remove the cartridge assembly (see "Disassembly").
Slowly turn on both hot and cold supplies and thoroughly flush out the body and lines. Close the hot and
cold supplies and replace the cartridge assembly (see "Reassembly"), turn on both supplies and check the system
for leaks.

If the balancing spool becomes stuck, it will be apparent at the trim-out test in that the valve will deliver only a
small trickle of water, or it will deliver only hot or cold water. If this occurs, proceed as follows:

Make sure that both the hot and cold water service lines are "ON". Also make sure that both rubber stop valves
are open (stop models). The valve WILL NOT OPERATE unless both supplies are "ON".

If the valve still does not function properly, turn off BOTH the hot and cold supplies and remove the cartridge
assembly. A cartridge twisting tool is required for this. The inner spool in the cartridge assembly should shake
back and forth freely. If this does not happen, remove the stem assembly from the cartridge sleeve, remove the
cap from the stem assembly and remove the balance spool. Sometimes the stem assembly may have to be jarred

to free the spool. Carefully clean any foreign material from the balance spool and stem assembly and reassemble
(see  illustration).  CAUTION:  DO  NOT  DAMAGE  O-RINGS. The  spool  should  move  back  and  forth  after  the  stem
assembly is cleaned. If spool still does not free up, replace the entire cartridge assembly. 

Make  sure  O-rings  are  free  of  foreign  material  and  are  lubricated.  Re-assemble  stem
assembly  into  cartridge  sleeve.  Re-assemble  cartridge  into  valve.  (See  "Reassembly").
Turn both water supplies on. The valve should function properly.

Slip-Fit spouts

C.C. SPOUT:  The Moen Slip Fit spout is designed with an O-ring seal. It is specifically
designed for installation with copper water tube. Lookout must be free from burrs
inside and out.  The edge must not be rolled inward from a dull tubing cutter.  The
outside surface must be free from nicks and scratches.

Press and twist the spout onto the lookout upside down.  Tighten the clamp screw
with a 5/32" hex wrench until it just starts to bind.  Turn spout upright into position
against the wall and finish tightening the clamp screw by hand.  The use of pliers or
another wrench on the hex wrench is not necessary.  Do not overtighten.

IPS SPOUT:

CAUTION:  

This spout is A.B.S. plastic and will crack when in contact with some pipe thread compounds.  

Please read the pipe compound label to be certain.  We recommend using thread seal tape thread sealant.

Screw tub spout onto pipe and tighten by hand.  If final turn by wrench is needed, use small wrench with smooth jaws;otherwise, pad wrench teeth with rag.
Pull outward on spout while tightening to avoid scratching wall.  DO NOT INSERT TOOL INTO SPOUT END TO TURN SPOUT.

Reviews: