background image

Device Description Embedded HMI-PLC XV-23x-57

 

Hardware

Display Technology, Backlight

 

 

 

11 D

ISPLAY 

T

ECHNOLOGY

, B

ACKLIGHT

 

 

An FSTN mono LCD (passive) is used for the display. The image is produced by means of a backlight 
that varies in color and intensity on account of the individual LCD cells (pixels). 

The light of the backlight is produced by means of cold cathode tubes. The lifespan of these tubes is 
limited, and depends on the actual operating conditions. The intensity of the brightness and the 
number of start cycles are major factors in determining the lifespan of the tubes. Reducing the 
brightness (adjustable via software) can considerably increase the lifespan of the device. Frequent 
switching, particularly at low temperatures, will reduce the lifespan of the unit.  

 

Therefore avoid the frequent switching on and off of the backlight or the entire system. Minimising the 
brightness required is more effective than reducing the frequent on/off switching. 

 

Î

 Further information: PANEL with WindowsCE [3] 

 

 

 

 

26

 

12/05 AWB2776-1581GB

© by Moeller GmbH

 

Summary of Contents for XV-23-57 Series

Page 1: ...Embedded HMI PLC XV 23x 57 Device Description 12 05 AWB2776 1581GB Think future Switch to green ...

Page 2: ...005 Edition date 11 05 Moeller GmbH Bonn Author Peter Zuber All rights reserved also for the translation None of this manual may be reproduced or processed duplicated or distributed by electronic systems in any form print photocopy microfilm or any other process without the written permission of Moeller GmbH Bonn Subject to modifications 2 12 05 AWB2776 1571GB by Moeller GmbH ...

Page 3: ...recognized for faults arising from the improper handling of devices and modules The devices even by means of communication should not be used for the implementation of any safety functions relating to the protection of personnel and machinery No liability is accepted for claims for damages arising from a failure or functional defect in the device All data specified in this document does not repres...

Page 4: ...face variants 14 4 6 1 CAN 14 4 6 2 MPI Profibus DP 15 4 6 3 System Port RS232 16 5 System Control Button CTRL 17 6 System Settings 18 7 CompactFlash Slot 19 8 Function and Control LEDs 20 9 Mounting instructions 21 9 1 General mounting instructions 21 9 2 Standard front 22 9 3 Mechanical dimensions 23 9 4 Front panel cutout Standard front 24 10 Notes on the touch screen 25 10 1 Resistive touch 25...

Page 5: ...rial damage may occur if the related safety measures are not implemented The individual Warning pictograms have the following meaning Attention General Is an instruction that must be strictly observed in order to protect oneself and the device from hazards relating to the operation of the device and to ensure the proper use of the device Attention Dangerous voltage There is a danger of electric sh...

Page 6: ...FTP server remote client server OPC client server printing via Ethernet UNICODE support and many additional features fulfill every possible need BENEFIT The operating system the application programs and data can be exchanged easily without any other technical resources FLEXIBILITY In conjunction with the integral PLC the devices can be expanded to become the heart of the automation system Third pa...

Page 7: ...the terminals technical data commissioning operating and maintenance 2 3 LIST OF DOCUMENTS Subject Document Doc No 1 Installation Installation instructions General wiring instructions AWB2776 1568GB 2 Networks Networks in brief AWB2776 1569GB 3 Windows CE PANEL with WindowsCE AWB2776 1553GB this list of documents is not final 12 05 AWB2776 1581GB by Moeller GmbH 7 ...

Page 8: ... Profibus DP not isolated XV 230 57CNN x 1x CAN not isolated 3 1 SCOPE OF DELIVERY The delivery consists of the device version ordered and the following accessories Device version XV 23x 57 Resistive touch Standard front x 1x Accessories enclosed 8 fixing brackets for mounting the device 8 hexagon type threaded pins for fixing brackets Sealing strip Power supply connector OS Flash fitted Resistive...

Page 9: ... OVERVIEW OF THE TERMINALS Connector panel XV 230 57xxx Ethernet Fieldbus View MPI Supply Connector panel XV 232 57BAS Ethernet System Port RS232 Supply Service side DIAG BFL USB Device The DIAG and BFL terminals should only be used for service tasks 12 05 AWB2776 1581GB by Moeller GmbH 9 ...

Page 10: ...57 Hardware Commissioning The Ethernet fieldbus and Supply terminals are located on the right of the device when viewed from the rear The terminal for the USB interface is located on the left of the device 10 12 05 AWB2776 1581GB by Moeller GmbH ...

Page 11: ...CTION TO THE POWER SUPPLY System supply 24 VDC SELV safety extra low voltage Not isolated Current consumption Î chapter 14 Fuse protection Internal fuse protection against reverse polarity Connector panel Connected to GND terminal plastic housing isolated Terminal type Screw terminal screwdriver No 3 pluggable Cross section min 0 75 mm2 max 2 5 mm2 lead or wire min AWG24 max AWG12 Stripping length...

Page 12: ...with shielded twisted pair cables STP or UTP and shielded RJ45 plug connectors The maximum permissible cable length is 100 m See also the specification as per EIA TIA 568 TSB 36 When preparing the cables it must be ensured that the cable shield is correctly connected to the connector casing A crossover cable must be used for connecting one device with another A 1 1 cable must be used when using a ...

Page 13: ... USB 1 1 Cabling Only use USB standard cables with a shield When preparing the cables it must be ensured that the cable shield is correctly connected to the connector casing The maximum permissible cable length is 5 m Î Further information Installation instructions General wiring instructions 1 12 05 AWB2776 1581GB by Moeller GmbH 13 ...

Page 14: ...2 6 1 dnc Do not connect Pin 3 and 6 0V are both connected internally to the CAN reference potential Pins 4 5 and 8 must not be connected The CAN bus driver is fed internally The CAN interface is not isolated The max baud rate is 1 Mbit s The terminating resistor must be provided externally e g in the connector and is not part of the device The CAN connector is not provided with a supply for third...

Page 15: ...nector 9pole 8 LINE A Receive Transmit Data A DSub female 9 TERM A Internal termination Data A 5 9 4 8 3 7 2 6 1 1 The 0V terminal must always be wired The MPI Profibus DP is not isolated The max baud rate is 1 5 Mbit s The terminating resistors should be provided externally in the plug connector in accordance with the Profibus standard Alternatively the termination in the plug connector can be im...

Page 16: ...ceive data 3 TxD Transmit data 4 DTR Data terminal ready 5 0 V Reference potential 6 DSR Ready for operation Data Set Ready 7 RTS Request to send Connector 9pole 8 CTS Clear to send DSub male 9 RI Ring indicator Case Shield Cable shield 5 9 4 8 3 7 2 6 1 The RS232 interface is not isolated The maximum baud rate is 115200 Kbit s Î Further information Installation instructions General wiring instruc...

Page 17: ...he system functions of the operating system Î Further information on the exact functions PANEL with WindowsCE 3 The Control button is located on the side of the CompactFlash slot Ensure the accessibility of the device when it is mounted Viewed from the rear the Control button is accessible on the left Control button 12 05 AWB2776 1581GB by Moeller GmbH 17 ...

Page 18: ...57 Hardware System Settings 6 SYSTEM SETTINGS This is where network display date time settings etc are entered These can be set via Start Programs Control Panel Î Further information PANEL with WindowsCE 3 18 12 05 AWB2776 1581GB by Moeller GmbH ...

Page 19: ...ept any liability for consequential damage arising from the use of CompactFlash cards offered by other suppliers Viewed from the rear the CompactFlash slot is accessible on the left View with CompactFlash lock open View with CompactFlash lock closed The CompactFlash card must not be fitted removed when the power supply is switched on Removing the CompactFlash card during operation access to Compac...

Page 20: ...TION AND CONTROL LEDS The XV 23x 57 is provided with the following LEDs for monitoring functions on the unit Ethernet ACT and LINK ETHERNET 1 LINK green Lit Active network connected and detected 2 ACT yellow Flashing Ethernet active data traffic 1 2 20 12 05 AWB2776 1581GB by Moeller GmbH ...

Page 21: ...nsure unobstructed air convection Hot components such as a heavily loaded transformer must have a clearance of at least 15 cm Avoid the exposure of the flat screen to direct sunlight The sunlight UV component reduces the lifespan of the LCD crystals The cooling slots must always be free in order to ensure the proper cooling of the system Avoid the exposure of the flat screen to direct sunlight Ens...

Page 22: ...evice from the front into the cutout of the front panel 3 Fasten the rear of the device at the two corners on the top and bottom with at least 4 of the fixing brackets provided maximum torque 0 15 Nm The 4 additional fixing brackets are required for mounting to IP65 or in the Ex Zone 22 These brackets are positioned in the middle of each side Groove for seal Holes for fixing brackets central for I...

Page 23: ...Hardware Device Description Embedded HMI PLC XV 23x 57 Mounting instructions 9 3 MECHANICAL DIMENSIONS 12 05 AWB2776 1581GB by Moeller GmbH 23 ...

Page 24: ...instructions 9 4 FRONT PANEL CUTOUT STANDARD FRONT Front panel cutout 198 0 1 0 mm x 142 0 1 0 mm 198 0 1 0 142 0 1 0 The front panel must not exceed a maximum thickness of 5mm due to the clamping range of the fixing brackets 24 12 05 AWB2776 1581GB by Moeller GmbH ...

Page 25: ... with a special pen supplied with the accessories or with a finger When wearing gloves these must be clean and must not be covered with abrasive dust or sharp particles The touch panel must not be operated with pointed objects or any writing equipment pens pencil etc Calibration The resistive touch panel has to be calibrated on initial startup In a dialog the marked position must be touched with t...

Page 26: ...n the actual operating conditions The intensity of the brightness and the number of start cycles are major factors in determining the lifespan of the tubes Reducing the brightness adjustable via software can considerably increase the lifespan of the device Frequent switching particularly at low temperatures will reduce the lifespan of the unit Therefore avoid the frequent switching on and off of t...

Page 27: ...repair centres In this case please contact your local PANEL dealer or the Technical Support at Moeller GmbH manufacturer address Î chapter 15 The warranty is not applicable if any modifications are made to the device that are not described in this document Transport The original packaging should preferably be used for transporting the device 12 05 AWB2776 1581GB by Moeller GmbH 27 ...

Page 28: ...r their proper disposal Special note The device contains a soldered lithium battery The LCD unit is fitted with a fluorescent tube for the backlight This contains mercury Materials device Housing PET Front plate PET Front glass Glass with foil touch sensor Foil PET Materials packaging Boxes Cardboard Transport protection PET Plastic bag PET 28 12 05 AWB2776 1581GB by Moeller GmbH ...

Page 29: ...nection Sub D 9 pole male CAN Type CAN not isolated Connection CiA Sub D 9 pole female MPI Type MPI Profibus DP not isolated Connection Sub D 9 pole female CompactFlash Slot Type CompactFlash Card Type I II CompactFlash Spec 1 4 Level 0 only NVSRAM Type 100 bytes FLASH emulated Flash Type 1 5 MByte Power supply Rated voltage 24 VDC SELV safety extra low voltage Voltage range 20 4 28 8 VDC rms abso...

Page 30: ...bient conditions Operating climate 0 50 C 10 90 rel air humidity non condensing Storage climate 20 60 C 10 90 rel air humidity non condensing Vibration Shock Fall test Vibration IEC68 2 6 Shock IEC68 2 27 Fall test IEC68 2 32 EMC CE EN 61000 6 2 EN 61000 6 4 EN 61000 6 3 EN 61131 2 Safety EN60950 UL60950 UL Explosion protection CE Zone 22 Category 3D Product standards EN 50178 Electrical equipment...

Page 31: ...n the nameplate II 3D X T 70 C EEx II IP5x The X on the nameplate stands for Must not be subjected to dangerous blows and nor erected in the tracks of cranes In order to achieve protection compliant with IP5x installation must be carried out with the supplied seal and the optional fixing bracket kit for IP65 Ambient temperature range 0 C Ta 50 C Applicable standards EN 50014 Electrical apparatus f...

Page 32: ...V 23x 57 Hardware EU Conformity Safety Moeller GmbH Industrieautomation Hein Moeller Str 7 11 D 53115 Bonn Tel 49 0228 602 0 Fax 41 0228 602 2275 E Mail info moeller net Internet http www moeller net 32 12 05 AWB2776 1581GB by Moeller GmbH ...

Reviews: