Menu overview of the operator
module
07/04 AWB2700-1428GB
46
Basic menu
After the power supply is switched on or after a reboot, the display
shows messages relating to the startup operation. After a startup,
the basic menu may show the following messages:
In the
first line
in addition to the time, instructions for the
diagnostics (!), and for protection with a password (+) and the
OMS position (P = RUN-P) are displayed.
The
second line
shows the current status of the PLC.
The
third line
shows the name of the executable program. If there
is no executable program in the PLC, the message “PROG: ???” is
displayed.
If the cursor is positioned next to MAIN MENU, you can turn the
menu selector switch to PASSWORD (if one has been activated) or
DISPLAY and select the item by pressing the switch.
The MAIN MENU can be reached by positioning the cursor on this
menu item and pressing the MSS.
Use the menu item BACK to return to the basic menu.
DISPLAY menu
a
also: Display a text from the user program.
The first three lines (3
x
12 characters) of the DISPLAY menu are
reserved for displaying information from the user program.
The function must be permanently selected to execute this feature.
To do this turn the MSS in the basic menu to menu item DISPLAY.
Press the MSS to delete the display in STOP mode, or show the text
in RUN mode.
Use BACK to return to the basic menu.
MAIN MENU
MAIN MENU: DIAGNOSTICS
Calling this menu will display the following menu items:
EVENT
When an event occurs, this is indicated by the exclamation mark
in the basic menu. The messages are displayed with date and time,
e.g.
If, for example, the message “STOP-BP” is shown, then the CPU
has reached a breakpoint in the execution of the program.
The last message that was received will be displayed. Messages
that were already received can be displayed by turning the MSS.
ERROR
Is dealt with as in the section EVENT.
An error that has occurred is indicated by the SF (central error)
LED.
CLEAR
All event and error messages will be deleted.
Time, diagnostics
PLC status
Program name
MAIN MENU
+ = Locked with a password
P = OMS status
(!)
An exclamation mark indicates the presence of an
unacknowledged event message. The type of error, together
with date and time, is displayed in the Diagnostics menu under
ERROR. As soon as you call up the menu item EVENT in the
diagnostics menu, the exclamation mark is deleted.
This message and any other messages present can be cleared
via the menu item DELETE.
(+)
A “+” appears if access is protected by a password.
In this case, the main menu can not be called up until you have
entered the password. After the correct password has been
entered, the main menu will be displayed.
Entering an incorrect password will return you to the
PASSWORD menu.
(X)
The displayed letters S = STOP, P = RUN-P, R = RUN correspond
to the position of the operating mode selector switch.
This status information can be different to the information in
the second line.
A closed or open rectangle indicates that the OMS has been
switched to the MRES position.
15:21:10 !+P
RUN-P
SAWING.PRO
>MAIN MENU
MAIN MENU:
DIAGNOSTICS
PROGRAM
RECIPE
DEVICE
SYSTEM
BACK
DIAGNOSTICS:
EVENT
ERROR
DELETE
BACK
27.07_18:35
STOP PROGR.
ABC.PRO