Moeller Teleservice XC100 Hardware, Engineering, Configuration Download Page 1

Moeller GmbH
Industrieautomation
Hein-Moeller-Straße 7–11
D-53115 Bonn

E-Mail: [email protected]
Internet: www.moeller.net

© 2002 by Moeller GmbH
Subject to alteration
AWB2724-1490GB xx/xx/Ki 07/04
Printed in the Federal Republic of Germany  (0x/02)
Article No.: xxxxxx

A

A

Think future. Switch to green.

Think future. Switch to green.

Systems

Industrial Automation

Hardware, Engineering, Configuration

07/04 AWB2724-1490GB

Teleservice
XC100

Building Automation

Summary of Contents for Teleservice XC100

Page 1: ...2 by Moeller GmbH Subject to alteration AWB2724 1490GB xx xx Ki 07 04 Printed in the Federal Republic of Germany 0x 02 Article No xxxxxx A A Think future Switch to green Think future Switch to green S...

Page 2: ...l chapter Moeller GmbH 53105 Bonn Author Werner Albrecht Editor Thomas Kracht Translator David Long All rights reserved including those of the translation No part of this manual may be reproduced in a...

Page 3: ...ey are well protected against unintentional operation Suitable safety hardware and software measures should be implemented for the I O interface so that a line or wire breakage on the signal side does...

Page 4: ...states even for a short time If necessary emergency stop devices should be implemented Wherever faults in the automation system may cause damage to persons or property external measures must be imple...

Page 5: ...nection PC modem or modem XC100 XC200 7 Connection PC TD32B modem 7 Cable layout 7 Modem TD32B XC100 XC200 connection 8 Cable layout 8 Connection modem modem 8 Telecontrol cable connection 8 Handshake...

Page 6: ...07 04 AWB2724 1490GB 2...

Page 7: ...are the first pages of Chapters and empty pages at the end of Chapters Further documentation XSoft Programming software h1437g pdf XI OC signal modules Hardware and engineering h1452g pdf XC CPU101 Ha...

Page 8: ...07 04 AWB2724 1490GB 4...

Page 9: ...s and the connection therefore has to be established via analog modem and leased or dial up line The telecontrol service enables user program download ONLINE modification and status indication in the...

Page 10: ...07 04 AWB2724 1490GB 6...

Page 11: ...e layout figure 2 shows the necessary connection between the COM1 2 interface on the PC and the RS 232 interface on the modem Since handshake signals are not being used a link is required between term...

Page 12: ...C100 XC200 please note the following The TD32B modem is set to hardware handshake with RTS CTS ex works As a handshake signal is not available with the XC100 XC200 the signal will need to be simulated...

Page 13: ...llowing diagram shows the telecontrol connection via the terminal block on the left at the bottom of the modem or at the RJ 12 connector If the telecontrol connection is made at the terminal block the...

Page 14: ...function 0 I x x I I x x Leased lines dial function I I x x x x I x Negotiation of the connection is not interrupted by incoming signals x x I x x x x I Escape sequence disabled commands are ignored...

Page 15: ...x Automatic speed and format setting 0 0 0 0 x x x x I 0 0 0 x x x x 300 Bit s I 0 0 0 x x x x 0 I 0 0 x x x x 600 Bit s 0 I 0 0 x x x x I I 0 0 x x x x 1 200 Bit s I I 0 0 x x x x 0 0 I 0 x x x x 2...

Page 16: ...x x x V 32 up to 9 600 Bit s 0 0 0 I x x x x I 0 0 I x x x x V 32 up to 12 000 Bit s I 0 0 I x x x x 0 I 0 I x x x x V 32 up to 14 400 Bit s 0 I 0 I x x x x I I I I x x x x Auto detect mode I I I I x...

Page 17: ...recognised ANS is On continuously while an incoming call is being answered and subsequently dims once the call has been answered REL The LED flashes when the modem is in fault correction mode or in c...

Page 18: ...07 04 AWB2724 1490GB 14...

Page 19: ...parameters l New After you have defined the communication connection type and name confirm with OK A new window opens after confirmation Enter the communication specific connection parameters Complet...

Page 20: ...PLC via Online Log in X Load the user program into the PLC with the Log in command X Start the PLC with the START command The status display is activated ONLINE modification For a connection via a lea...

Page 21: ...em modem 8 PC TD32B modem 7 TD32B modem PC 8 Connection structure for leased line and dial up line 7 D Dial up line 9 DIP switch 10 Download user program 16 E Establish connection between PC and contr...