Head station RA-IN
01/08 AWB2190-1430GB
34
Diagnose and status via LEDs
LED
colour
meaning
no signal
flashes
signal
AS-Interface
®
Power
green
The master has sufficient voltage
No voltage
–
Voltage applied
AS-Interface
®
Error
red
Configuration error: At least one configured
slave is missing or the actual configuration
of at least one configured and detected
slave does not match the target
configuration.
If both configuration and I/O errors are
present, only the configuration error is
displayed.
no fault
I/O error at at least
one AS-Interface
®
slave
Communication error,
e.g. slave has no
address
UASi
green
AS-Interface
®
circuit has sufficient voltage
No voltage
–
Voltage supply
sufficient
prj mode
yellow
RA-IN is in engineering mode
Operation mode
–
Engineering mode
prg enable
green
Automatic address programming is
possible. In protected operation mode
exactly one slave is missing. This can be
replaced with an equivalent slave with
address 0. The master automatically
assigns an address to the new slave, which
cancels the configuration error.
Operation mode
–
Address programming
possible
ASi active
green
Normal operation is active
No connection with
AS-Interface
®
Display of B-slaves
normal operation
PROFIBUS
green
Assignment to RA-IN
RA-IN is not
assigned to a
PROFIBUS master
–
RA-IN is assigned to a
PROFIBUS master