01/08 AWB2190-1430GB
RA-SP and keypad DEX-KEY-10
115
RA-SP and keypad DEX-KEY-10
support
: and enter the document number in the Quick Search field.
On first use, keypad DEX-KEX-10 must be configured speed
control unit RA-. Do this as follows:
X
Press and hold the RMT and PRG keys at the same time and
switch on the supply voltage. All LEDs light up.
X
Release the RMT and PRG keys.
The cursor
Â
flashes next to the active function or the activated
input value. To move the cursor, select a function and change the
values, use the arrow keys
í
,
Í
and
Ú
. Changed values and
functions are indicated by an asterisk (*) and can be saved with
the ENTER key. To change the settings or return to the previous
settings without saving any changes, use the arrow keys
í
,
Í
and
Ú
.
X
Select CONFIGURATION with the ENTER key.
BPS (bits per second) indicates the data transfer rate. For RA-SP,
this value should be set to 4800.
X
Press arrow key
Ú
.
X
Press arrow key
í
.
X
Press arrow key
Ú
twice and confirm selection DRW2 with the
ENTER key.
X
Then press the RMT key twice. All LEDs except POWER and RMT
go out. The keypad is now correctly configured.
Monitor menu of DEX-KEY-10
To call up the Monitor menu, press the MNT key. For RA-SP “TM
005.0 0.0Hz” on the left indicates the reference value from spindle
potentiometer
n
0
(default = 5 Hz) and on the right the output
frequency is indicated.
To change the settings in the Monitor menu, use arrow keys
Í
and
Ú
. In addition to the indication of reference and actual values and
error messages, inputs can also be made.
To view the acceleration time, press arrow key
Í
.
h
Caution!
During operation or parameterization with the remote
HMI device contact faults orwire breakages can cause the
Stop function to fail. Make sure that a second Stop
function is enabled in all operating states. If necessary an
Emergency Stop must be forced.
Figure 119: DEX-KEY-10 keypad
RMT
ALARM
FWD
REV
PRG
POWER
RUN
READ
COPY
MNT
PRG
ENTER
LOCAL MODE
CONFIGURATION
DIAGNOSE
h
The RMT and
ú
keys have no function in connection with
the RA-SP.
BPS
4800
OPERATOR TYPE
SRW
OPERATOR TYPE
SRW
OPERATOR TYPE
*
DRW2
TM 005.0
0.0Hz