Speed controller RA-SP
01/08 AWB2190-1430GB
112
Diagnose and status via LEDs
LED
Colour
Meaning
no signal
flashes
Signal
AS-Interface
®
Power
green
AS-Interface
®
-voltage
missing
–
applied
AS-Interface
®
Fault
red
AS-Interface
®
-fault
no fault
–
Communication
error, e.g. slave
has no address.
UV
green
Auxiliary power 24 V internal or
external for RA-SP-HE… and DIP
pole 8 = 1
missing
–
applied
FWD
green
Clockwise
not actuated
Not actuated on RA-SP-HE…
because:
• light barrier has been reached
in interlocked manual
operation or quick stop
• 400 V supply failed and
returned in manual mode
1)
• 24 V supply failed and
returned with DIP pole 8 = 1
in manual mode
1)
Start Forward
rotating field
REV
green
Anti-clockwise
not actuated
Start Reverse
rotating field
–
–
Automatic, indicated by key-
switch
–
–
–
Motor:
red
Group error from power module,
thermistor, motor plug not
connected.
In addition, on RA-SP-HE:
• DIP switch position invalid
• Overload/short-circuit I3/I4
no fault
–
applied
I 3, I4
RA-SP…342/343
RA-SP-HE
green
external input via M12 socket,
PIN 4
not actuated
–
actuated
RA-SP-HE
red
external input via M12 socket,
PIN 2
not actuated
–
actuated
yellow
external input via M12 socket,
PIN 2 + 4
not actuated
–
actuated
1) Automatic restarting after a 400 V power failure is prevented. To continue manual operation, a Reset command must be issued (set key-switch to OFF).