Speed controller RA-SP
01/08 AWB2190-1430GB
102
Screen motor cable
X
Strip the cable’s outer sheath and pull back the screen braid.
X
Strands B1/B2 (brake) and T1/T2 (thermistor) have a separate
screen braid. Expose these.
X
Push the motor cable’s screen braid forward so as to cover the
screen braids of strands B1/B2 and T1/T2 over a large area.
X
Secure the clip where the braids overlap.
X
Secure the braid ends with a rubber grommet or with insulating
tape to prevent the braid from fraying.
X
Connect the intertwisted strands (U, V, W and PE) and the
separately twisted strands B1/B2 and T1/T2 to the
corresponding terminals in the motor or in the connector (SET-
M4-A).
X
Connect the screen braids to earth potential over a large area:
– in the motor connection cable’s plug
– in the motor’s screw connections.
The illustrated screen clamp provides an example of large-area
earth connections.
Figure 108: EMC-conformant connection of the screened motor cable
U1, V1, W1, PE
B1/B2
T1/T2
Summary of Contents for Rapid Link
Page 10: ...01 08 AWB2190 1430GB 6 ...
Page 40: ...01 08 AWB2190 1430GB 36 ...
Page 48: ...01 08 AWB2190 1430GB 44 ...
Page 70: ...01 08 AWB2190 1430GB 66 ...
Page 146: ...01 08 AWB2190 1430GB 142 ...
Page 162: ...01 08 AWB2190 1430GB 158 ...