08/07 AWB1230-1407GB
5 – 17
Spring-loaded terminals
5.4.2
Sliding contact module
Retrofitting
A single piece sliding contact module is also available with standard
screw terminals.
Single-piece sliding contact modules don´t require a control circuit
plug. The cable is directly connected to the sliding contact module.
5.4.3
Control circuit plug
Screw terminals
Spring-loaded terminals
Attach guide tongues
(fixed-mounted circuit-breaker only)
(1)
Connection area with sliding contact modules
(2)
Sliding contact module
Connecting wires
3.0 × 0.6
1
2
(1)
(2)
0769
3.0 × 0.6
3.0 × 0.6
2 terminals in parallel per contact
3.0 × 0.6
Back side of
auxiliary connector