DVI-Panel
Touch-Panels for Industrial Automation
Device Description
Mounting instructions
24
02/05 AWB2720-1524GB © 2005 by Moeller GmbH
7.3 M
OUNTING IN THE FRONT PANEL
– ATEX
All XV-DVI series devices are designed for use in machines and plants
which are placed in hazard zone 22.
The XV-DVI series devices fulfill the requirements for
machines and plants which are placed in hazard zone 22
only, if they are mounted in enclosures or other devices
which fulfill the requirements of ATEX standards.
Especially IP65 requirements must be fulfilled and the
surface temperature must not exceed 80°C.
For a save installation, operation and mounting please
notice the mounting and type label instructions. (see
section 7.2)
7.4 F
RONT PANEL CUTOUT
6,4“
The device requires a mounting cutout of WxH:
198 +0/-1 mm x 142 +0/-1 mm
The thickness of the front panel must not exceed 5 mm.