background image

LINEAR150

LINEAR ModuleX

The fixture is for indoor use only in general conditions.

Can not be used following conditions (Causes of falling, electrocution and fire)

●Ambient temperature under 0℃ and over 35℃

●High humidity
●Outside
●On the floor

●Insulated inside of ceiling

20cm〜

10cm〜

●Vibrated or shocked areas
●Areas get direct sunlight

●Inclined, uneven surface

●Ceiling which canʼt hold the fixture weight
●On the wall
●Places affected by wind or air-conditioner machine
●Near fire
●Dusty areas, corrosive gas outbreaks areas

Before

installation

Warning

Caution

Please contact if you are not able to judge whether installation 

environment is suitable to the places or not.

Insulator

Insulator

Insulator

To install the fixture safely《 Read carefully and follow all the  instructions in the guide 》

Warning :  Failure to install the fixture properly could result in personal injury.

Failure to install the fixture properly could result in property damage.

: Prohibited
: Strict observance

Caution : 

Warning

Please follow the fixturesʼ indication or specification for the distance of irradiated area.

 (Causes of change in shape, change in color of irradiated objects)

At lighting

fixture 

installation

Caution

Make sure the construction will not affect any fire prevention systems such as sprinkler by heat from the fixture. 

(Causes for improper operation)

Please follow the fixturesʼ instruction or this guide to install the fixture and lamp. (Causes of falling・electrification・fire)

Make sure to install all the parts of fixtures besides installation and mounting parts will not touch with any

objects both inside and outside of ceiling such as lighting track, etc. (Causes of falling・electrification・fire) 

Do not dismount or remodel fixtures. (Cause of electrification・fire・falling・broken fixtures)

Box

Cover maintenance

3/8”Bolt(Constructs Separately)

Ceiling board

(Constructs Separately)

Surface finish

Surface finish

Adjustable bracket

Ballast

Power wire

SX-LB146T

weight

SX-LB146CR

SX-LB146E

SX-LB146S/300

SX-LB146S/600

SX-LB146S/900

SX-LB146S/1200

SX-LB146C

weight

weight

weight

weight

weight

weight

weight

wide

wide

wide

wide

wide

End-Type

T-Type

Cross-Type

Coner-Type

300

600

900

1200

SX-LB140E

SX-LB140S/300

SX-LB140S/600

SX-LB140S/900

SX-LB140S/1200

SX-LB140C

SX-LB140CR

SX-LB140T

weight

weight

weight

weight

weight

weight

weight

weight

wide

wide

wide

wide

wide

Mounting Depth

Mounting Depth

Fixture Installing Rail

Fixture (sold separately)

Installation Guide    Mounting

Installation Guide

Mounting

Discontinued product

Reviews: