background image

  

 

1.3 ELECTRICAL DATA 

 

BASIC HEATING ELEMENTS 

 

MODEL 

65/40 GR 

65/70 GR 

65/70 BE 

RATED VOLTAGE 

230V~  50/60 Hz 

POWER  kW 

0,5 

0,76 

0,76 

CABLE DIAMETER 

POWER SUPPLY 

H05RN-F 

5 x 1 mm² 

H05RN-F 

5 x 1 mm² 

H05RN-F 

5 x 1.5 mm² 

DIMENSIONS mm 

WIDTH 

DEPTH 

HEIGHT 

 

310 

530 

50 

 

515 

530 

50 

 

700 

540 

570 

 

The data plate contains all data which is required for installation and is located at the 

bottom of the front left-hand side. 

 

 

 

THERMOSTAT HEATING ELEMENTS 

 

MODEL 

65/40 GRT 

65/70 GRT 

65/70 BET 

RATED VOLTAGE 

230V~  50/60 Hz 

POWER  kW 

0,5 

0,76 

0,76 

CABLE DIAMETER 

POWER SUPPLY 

H05RN-F 

5 x 1.5 mm² 

H05RN-F 

5 x 1.5 mm² 

H05RN-F 

5 x 1.5 mm² 

DIMENSIONS mm 

WIDTH 

DEPTH 

HEIGHT 

 

310 

530 

50 

 

515 

530 

50 

 

700 

540 

570 

 

The data plate contains all data which is required for installation and is located at the 

bottom of the front left-hand side. 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 65/40 GR

Page 1: ...MOD 65 40 GR 65 40 GRT 65 70 GR 65 70 GRT 65 70 BE 65 70 BET ELECTRIC BASE UNIT AND HEATING ELEMENTS Code 252 112 10 ...

Page 2: ...rams 1 3 Electrical data 1 4 Rating plate data 2 Preparing for installation 2 1 Laws technical regulations and general rules 2 2 Installation 2 2 1 Electrical connection 2 2 1 1 Equipotential connection for electric base unit Paragraph User connections 3 Starting up 3 1 Switching on and off 4 Maintenance cleaning and care ...

Page 3: ... elements are made in compliance with the essential requirements established by the EEC directives in agreement with the EEC 73 23 Low Voltage Directive with the EEC 89 336 EMC Directive supplemented by the CE mark according to the EEC Directive 93 68 ...

Page 4: ...ins all data which is required for installation and is located at the bottom of the front left hand side THERMOSTAT HEATING ELEMENTS MODEL 65 40 GRT 65 70 GRT 65 70 BET RATED VOLTAGE 230V 50 60 Hz POWER kW 0 5 0 76 0 76 CABLE DIAMETER POWER SUPPLY H05RN F 5 x 1 5 mm H05RN F 5 x 1 5 mm H05RN F 5 x 1 5 mm DIMENSIONS mm WIDTH DEPTH HEIGHT 310 530 50 515 530 50 700 540 570 The data plate contains all ...

Page 5: ...ould install start and service the appliance Installation must be carried out in compliance with the laws in force in the country where the appliance is installed The manufacturer declines all responsibility if the appliance malfunctions due to incorrect installation tampering improper use bad maintenance failure to comply with the local laws and inexperience in using the appliance 2 2 1 ELECTRICA...

Page 6: ...ess must be verified in accordance with the relative current laws The connection is on the side of the covering of the group and is marked with a plate that says EQUIPOTENTIAL NOTE the manufacturer declines all responsibility if the above described accident prevention rules are not complied with Terminali cavetti di terra apparecchiatura Unit earth terminal wires ...

Page 7: ...yellow indicator light shows that the heating element is and will be operating until the temperature has been reached To turn it off turn the knob counter clockwise until the switch clicks in position 0 4 MAINTENANCE CLEANING AND CARE Always disconnect the appliance from the electricity mains before embarking on any maintenance work Have a specialised technician check the condition of the applianc...