background image

 
 
 

 

 

 

 
POWER CORD INSTALLATION

 

1.  Remove  the  screws  at  the  bottom  of  the 

unit.  Lift  up  the  main  switch  knob  and  the 
power  knob  to  make  it  free.  Remove  the 
front plate (the cover) gently. 

 

 

2.  Remove  the  pressing  plate  of  the  power 

cord and keep the screws. 

 

 

3.  Gash  the  middle  of  the  power  cord  jacket 

with  a  sharp  knife  in  order  to  insert  the 
power cord (lines).  

 

 

 
4.  Insert the  power cord (lines) into the jacket 

for installation of the wire pressing plate. 

 

 

5.  Tighten  the  wire-pressing  plate  with  the 

screws  to  primary  position;  make  sure  that 
the power cord doesn’t come loose when it 
is pulled at 60N force. 

 

 

6.  Connect the end of the power cord to wiring 

terminals;  the  method  is  as  shown  in  the 
image. 

 

 
 

 
 
 
 
 
 
 

 

Part 3:

 

Installation 

 

Note :

 The installation of every ends of neutral line (blue), live line (brown /red) and 

earth line (green/yellow) should be corresponding to the other end on wiring 
terminals. 

Summary of Contents for EL 2 W

Page 1: ...User Manual Book Electric Instant Water Heater Veloce Series EL 2D B EL 2 W ...

Page 2: ... aim to deliver stylishly designed products equipped with state of the art technology to assist you in your daily activities This is your guidebook containing everything you need to know about our product Please reach us if you need further assistance or other information via our Customer Care or our official website www MODENA com ...

Page 3: ...E Introduction 2 Part 1 Name of Parts 4 Part 2 Important Safety Information 5 Part 3 Installation 6 Part 4 How to Use 8 Part 5 Maintenance 10 Part 6 Troubleshooting 10 Part 7 Specification 11 Part 8 Wiring Diagram 12 ...

Page 4: ...4 EI 2D B El 2 W Part 1 Name of Parts ...

Page 5: ...ff the Miniature Circuit Breaker MCB in advance to protect the water heater against possible damage Inspect on the built in ELCB once a month to avoid a hazard to users such as damage to property serious injury or death Do cut off the power electricity supply before any maintenance Any maintenance or adjustment towards this product by non professional is highly prohibited The damaged power cord mu...

Page 6: ...er cord lines 4 Insert the power cord lines into the jacket for installation of the wire pressing plate 5 Tighten the wire pressing plate with the screws to primary position make sure that the power cord doesn t come loose when it is pulled at 60N force 6 Connect the end of the power cord to wiring terminals the method is as shown in the image Part 3 Installation Note The installation of every end...

Page 7: ...all by means of a drill and insert a plastic wall anchor fischer into the hole 4 Tighten one of the screws on the top and make sure that there is the certain distance between the head of the screw and the wall see below picture 5 Install the unit on the wall and tighten two screws at the bottom connect the wires and re install the top cover with the screws PLUMBING CONNECTION 1 The water valve wit...

Page 8: ...nding to the line in electric network WATER SUPPLY After all the process of the plumbing connection is finished open the water inlet valve of the product and supply the unit with the water to drain away the air inside until there is the stable water flow comes out from the shower head Check whether there is leakage at the joints connection or not If there is check whether the connecting parts are ...

Page 9: ... for EI 2D B or Earth and ELCB blue indicator lights will turn on for EI 2 W When the water flow exceeds 1 5L min rotate the knob clockwise to switch on the power switch the heating indicator light will be on and the unit will start to work LEAKAGE TEST EI 2D B When the water heater is working normally press the Test button If the leakage test circuit shows no issue the screen will off and this wa...

Page 10: ... seconds to drain away the impurities in the pipe before connecting the water source to the water heater If the unit has not been used for a long period of time check the water heater first before use Connect the water heater with power supply after the water flows out stably To avoid moisture do not spray water to the circuit breaker or the heater body directly Please cut off the power supply in ...

Page 11: ...ign is flickering EI 2D B 1 Ground damage 2 PCB error 1 Check the grounding 2 Contact MODENA Call center for repair ELCB indicator light is twinkling flicker EI 2 W Electricity leaks Contact MODENA Call center for repair Screen display E1 EI 2D B Power indicator light is twinkling flicker EI 2 W Temperature sensor is broken Change the temperature sensor Model EI 2D B EI 2 W Rated Voltage Frequency...

Page 12: ...12 EI 2D B EI 2 W Part 8 Wiring Diagram ...

Page 13: ...11 20 ...