background image

 
 
 

 

 

11 

 

off and the outlet water is 
cold. 

2. PCB error 
3. Water flow less than 1.5L/min 
4. Impurities clogging the rotor of 

water flow switch (water valve) 

2. Repair or replace the PCB 
3. Increase the water flow 
4. Change the flow sensor 
5. Open  the  flow  switch  and 

clean the rotor

 

The outlet water is cold.

 

1.  

Thermal Cut-out

 

is

 

disconnected (Screen display 
“E3” - EI 2D B) 

2. Heating elements is damaged. 

1. 

Press the “Reset” handle of 
the 

Thermal Cut-out

 after 

checking  

2. Change the heating elements 

No water flows out from the 
shower head. 

1. Water supply is cut off 
2. Water inlet valve is not open. 

1. Wait until the water supply is 

restored 

2. Open the water inlet valve  

The temperature of outlet 
water is inconsistent 

1. The water pressure is unstable  
2. The temperature of outlet 

water is too high - overheating 
protection is working 
excessively. 

Lowering the heating power, 
and make the water flow 
bigger. 

Safety sign is flickering 
 (EI 2D B) 

1. Ground damage 
2. PCB error.

 

1. Check the grounding 
2. Contact MODENA Call center 

for repair 

“ELCB” indicator light is 
twinkling flicker (EI 2 W) 

Electricity leaks 

Contact MODENA Call center 
for repair 

 Screen display E1 (EI 2D B)  

 

“Power”  indicator  light  is 
twinkling flicker (EI 2 W)

 

Temperature sensor is broken 

Change the temperature 
sensor 

 
 

 

 

Model

 

EI 2D B

 

EI 2 W

 

Rated Voltage / Frequency

 

220V / 50/60Hz

 

Rated Power

 

2400W 

Rated Current

 

0

11A 

Minimum Flow Rate

 

1.5 Liters/minute 

Water Output Temperature 

30 ~ 55

°

Working Pressure

 

0.03 ~ 0.3 MPa 

Protection Class

 

IP Rating

 

IP25 

Products Size

 

406 × 232 × 103 mm 

Color 

Brown 

White 

Temperature Display 

Yes 

No 

 
Specifications of this appliance may change without notice to improve the quality of the product. Figures in this 
manual  are  schematic  and  may  not  match  your  product  exactly.  Values  stated  on  the  machine  labels  or  in  the 
documentation accompanying it are obtained in laboratory in accordance with the relevant standards. Depending 
on operational and environmental conditions of the appliance, values may vary. 

 
 
 
 
 
 
 
 
 
 

Part 7: 

Specification 

Summary of Contents for EL 2 W

Page 1: ...User Manual Book Electric Instant Water Heater Veloce Series EL 2D B EL 2 W ...

Page 2: ... aim to deliver stylishly designed products equipped with state of the art technology to assist you in your daily activities This is your guidebook containing everything you need to know about our product Please reach us if you need further assistance or other information via our Customer Care or our official website www MODENA com ...

Page 3: ...E Introduction 2 Part 1 Name of Parts 4 Part 2 Important Safety Information 5 Part 3 Installation 6 Part 4 How to Use 8 Part 5 Maintenance 10 Part 6 Troubleshooting 10 Part 7 Specification 11 Part 8 Wiring Diagram 12 ...

Page 4: ...4 EI 2D B El 2 W Part 1 Name of Parts ...

Page 5: ...ff the Miniature Circuit Breaker MCB in advance to protect the water heater against possible damage Inspect on the built in ELCB once a month to avoid a hazard to users such as damage to property serious injury or death Do cut off the power electricity supply before any maintenance Any maintenance or adjustment towards this product by non professional is highly prohibited The damaged power cord mu...

Page 6: ...er cord lines 4 Insert the power cord lines into the jacket for installation of the wire pressing plate 5 Tighten the wire pressing plate with the screws to primary position make sure that the power cord doesn t come loose when it is pulled at 60N force 6 Connect the end of the power cord to wiring terminals the method is as shown in the image Part 3 Installation Note The installation of every end...

Page 7: ...all by means of a drill and insert a plastic wall anchor fischer into the hole 4 Tighten one of the screws on the top and make sure that there is the certain distance between the head of the screw and the wall see below picture 5 Install the unit on the wall and tighten two screws at the bottom connect the wires and re install the top cover with the screws PLUMBING CONNECTION 1 The water valve wit...

Page 8: ...nding to the line in electric network WATER SUPPLY After all the process of the plumbing connection is finished open the water inlet valve of the product and supply the unit with the water to drain away the air inside until there is the stable water flow comes out from the shower head Check whether there is leakage at the joints connection or not If there is check whether the connecting parts are ...

Page 9: ... for EI 2D B or Earth and ELCB blue indicator lights will turn on for EI 2 W When the water flow exceeds 1 5L min rotate the knob clockwise to switch on the power switch the heating indicator light will be on and the unit will start to work LEAKAGE TEST EI 2D B When the water heater is working normally press the Test button If the leakage test circuit shows no issue the screen will off and this wa...

Page 10: ... seconds to drain away the impurities in the pipe before connecting the water source to the water heater If the unit has not been used for a long period of time check the water heater first before use Connect the water heater with power supply after the water flows out stably To avoid moisture do not spray water to the circuit breaker or the heater body directly Please cut off the power supply in ...

Page 11: ...ign is flickering EI 2D B 1 Ground damage 2 PCB error 1 Check the grounding 2 Contact MODENA Call center for repair ELCB indicator light is twinkling flicker EI 2 W Electricity leaks Contact MODENA Call center for repair Screen display E1 EI 2D B Power indicator light is twinkling flicker EI 2 W Temperature sensor is broken Change the temperature sensor Model EI 2D B EI 2 W Rated Voltage Frequency...

Page 12: ...12 EI 2D B EI 2 W Part 8 Wiring Diagram ...