11
off and the outlet water is
cold.
2. PCB error
3. Water flow less than 1.5L/min
4. Impurities clogging the rotor of
water flow switch (water valve)
2. Repair or replace the PCB
3. Increase the water flow
4. Change the flow sensor
5. Open the flow switch and
clean the rotor
The outlet water is cold.
1.
Thermal Cut-out
is
disconnected (Screen display
“E3” - EI 2D B)
2. Heating elements is damaged.
1.
Press the “Reset” handle of
the
Thermal Cut-out
after
checking
2. Change the heating elements
No water flows out from the
shower head.
1. Water supply is cut off
2. Water inlet valve is not open.
1. Wait until the water supply is
restored
2. Open the water inlet valve
The temperature of outlet
water is inconsistent
1. The water pressure is unstable
2. The temperature of outlet
water is too high - overheating
protection is working
excessively.
Lowering the heating power,
and make the water flow
bigger.
Safety sign is flickering
(EI 2D B)
1. Ground damage
2. PCB error.
1. Check the grounding
2. Contact MODENA Call center
for repair
“ELCB” indicator light is
twinkling flicker (EI 2 W)
Electricity leaks
Contact MODENA Call center
for repair
Screen display E1 (EI 2D B)
“Power” indicator light is
twinkling flicker (EI 2 W)
Temperature sensor is broken
Change the temperature
sensor
Model
EI 2D B
EI 2 W
Rated Voltage / Frequency
220V / 50/60Hz
Rated Power
2400W
Rated Current
0
~
11A
Minimum Flow Rate
1.5 Liters/minute
Water Output Temperature
30 ~ 55
°
C
Working Pressure
0.03 ~ 0.3 MPa
Protection Class
I
IP Rating
IP25
Products Size
406 × 232 × 103 mm
Color
Brown
White
Temperature Display
Yes
No
Specifications of this appliance may change without notice to improve the quality of the product. Figures in this
manual are schematic and may not match your product exactly. Values stated on the machine labels or in the
documentation accompanying it are obtained in laboratory in accordance with the relevant standards. Depending
on operational and environmental conditions of the appliance, values may vary.
Part 7:
Specification