1. With the condition that the wall is strong enough, drill 2 holes with a diameter of 8 mm, and
the distance between the hole with another hole is 62 mm. Hole depth of approximately 45
mm.
2. The height of the holes should be spaced at least 500 mm from the floor and a distance of
200 mm from the side wall.
3. Insert fischer into the hole then screw wall hooks well and flat. Install the unit on a wall hook
so that the hook is properly put on the iron plate.
4. Connect the water pipes:
Before connecting the water pipes, install a safety valve on the incoming water pipe (blue
color). Safety valve should not be spinned too fast because it will damage the valve seat.
Connect the exit hole for water to exit the water pipe (red color).
Tap stopper must be connected to the water inlet pipe and water pipe out. Use seal tape
that can be connected to both.
Supplementary Pressure Relief Valves required for incoming water pipes if the water
pressure exceeds 0.5 MPa. If the water heater is located more than 7m from where you
are using a Water Heater, the addition of insulation on hot water pipes is recommended
to prevent the loss of heat source.
ES 30V, ES 50V, ES 80V & ES 100V
Pipe Connection
d. All pipes are of G1/2". Use a type of seal tape on the end of the entry of water heater
(Identification of the color blue) and reinstall the one-way safety tap properly.
e. Joining methods for multi-outlet pipe system.