![Mocon AMETEK Dansensor Lippke 5000 User Manual Download Page 127](http://html1.mh-extra.com/html/mocon/ametek-dansensor-lippke-5000/ametek-dansensor-lippke-5000_user-manual_1816852127.webp)
Dansensor
®
Lippke
®
5000
EN
User Guide
125
Basic specifications
Measuring range
1 - 5000 mbar
Displayed resolution
0 - 1000 mbar:
0,1 mbar
1000 - 5000 mbar:
1 mbar
Accuracy
1 - 350 mbar:
± 0.5 mbar or ±0.5% of reading
350 - 5000 mbar:
± 5 mbar or ±0.5% of reading
Repeatability
1 - 350 mbar:
Regulation at a fixed pressure: ± 0.5 mbar
Overshoot regulation to a fixed pressure:
≤ 1.5 mbar + 0.25% of set-point
350 - 5000 mbar:
Regulation at a fixed pressure: ± 3 mbar
Overshoot regulation to a fixed pressure:
≤ 5 mbar + 0.2% of set-point
Pressure units
mbar, mmHG or psi
Test time
1 - 500 sec.
Calibration interval
12 months
Data Collection
Number of test
300
definitions
Data collection
Test data from more than 1.000.000 tests
capacity
Collection type
Stand alone units:
Exported to CSV file
Using PC Software:
Local or external SQL database
Conformity
CE mark
China RoHS II
Other standards
ASTM F-1140, F-2054, F-2095, F-2096
CFR 21 part 11 (with PC SW or use label printer, stand-alone without printer not approved).
ISO 11607
Summary of Contents for AMETEK Dansensor Lippke 5000
Page 1: ...P N 380419 C 05 2022 UserGuide...
Page 2: ...This blank page has been inserted to enable double sided printing of the document...
Page 4: ...2 User Guide EN Dansensor Lippke 5000 P N 380419 C 05 2022...
Page 38: ...36 User Guide EN Dansensor Lippke 5000 P N 380419 C 05 2022...
Page 88: ...86 User Guide EN Dansensor Lippke 5000 P N 380419 C 05 2022...
Page 106: ...104 User Guide EN Dansensor Lippke 5000 P N 380419 C 05 2022...
Page 128: ...126 User Guide EN Dansensor Lippke 5000 P N 380419 C 05 2022...
Page 135: ...This blank page has been inserted to enable double sided printing of the document...
Page 136: ...0 0 VSPQF 4 3 OOFEFWFK 3JOHTUFE FONBSL 5FM JOGP EL NPDPO BNFUFL DPN XXX BNFUFLNPDPO DPN...