After the charger indicator’s light changes from red to green, keep charging the
batteries for 30 minutes to ensure they are full charged. Unplug the external wall plug
first, then unplug the cable from the control panel.
11.5
Over Discharge Protection
When the battery of the electric mobility chair runs out of power, the over discharge
protection device will shut the batteries off to protect them against excessive
discharge. Users should notice that when the over discharge protection device is
activated, the maximum speed of the mobility chair will be reduced.
11.6
Over Current Protection
The electric mobility chair is also equipped with an over-current protection device. If
the current provided to the motor is excessive, the electronic fuse will close the current.
If there is any malfunctioning when operating the mobility chair, the over-current
protection device will be activated, the driving wheels will stop rotating. In this
process, the fuse will cut off the current, prevent the motor from being damaged from
overheating. (See the control panel section)
11.7
Period Cleaning
Check whether the battery case, the positive and negative ends of the battery are
corroded or not.
Check whether the plastic battery box has been assembled completely.
Use battery cleaning tools - medium sandpaper to clean the battery port.