© MOBATIME
28 / 94
801299.00
6.5.6
Time source
Time source configuration.
DTS 4020.timebridge Moser-Baer AG
====================================
TIME SOURCE
1 Source configuration
2 Stratum configuration
3 Alarm delay for failure of the source 1min
4 Max. offset for time ok 250ns
5 Alarm big Offset to source 1000ns
6 Holdover TO 0s
98 Return and save
99 Return and discard changes
Enter desired menu number>
Path: 2 Configuration
2 Time handling
1 General source setting
1. Menu to configure source types and priorities
2. Menu to configure stratum
3. Alarm delay at failure of time source (minutes):
1min - 2'160min, default = 1
Error: “loss of time source TO”
4. Maximum offset for time source to set valid time in ns at start up.
(0-1’000’000ns)
For description of time source see chapter “8 Time administration“
5. When the offset to the active source exceeds this value, an error occurs.
6. After this time the device stops holdover and get in unsynchronized state by
means disable all outputs.