9.2
Device configuration with SNMP
If one or several variables are set in a configuration group with
Put
, the variable
dts4210????ConfigCmd
must be set at the end to 1 in the corresponding group. The
values of the entire configuration group are assumed from the DTS with this command
(1=Save).
As long as the accept command has not been set, the changed variables can be
restored to the old values by setting the
dts4210????ConfigCmd
variable to 2 (2=undo,
restore).
After sending the accept command, a dts4210ConfigChanged
Notification
is sent.
The definitions of the available variables can be taken from the MIB files.
Example:
Management-System
DTS
Put
dts4210FTPMode=1
Variable is set to 1 internally
Put
dts4210NetServicesConfigCmd=1
Configuration group is assumed
Sends dts4210ConfigChanged
Notification
with the new time
dts4210NetConfigChangedTime
9.3
DTS subagent SNMP notification
Protocol: SNMPv2c Notification
For
Notifications
to be sent out, SNMP must be switched on. In addition, at least one
receiver system must be configured.
9.3.1
Startup
[dts4210StartUp]
Sent out when the subagent for the DTS is started.
This
Notification
is always sent out, as soon as SNMP is activated and a destination
address is configured.
9.3.2
Shutdown
[dts4210Shutdown]
Sent out when the subagent for the DTS is stopped.
This
Notification
is always sent out, as soon as SNMP is activated and a destination
address is configured.