8.2.2 Sensitivity setting
Sensitivity
The parameter
“sensitivity” determines how quickly (or
respectively how aggressively) the controller reacts to a
deviation.
The setting range starts from 1 (low sensitivity) to 10 (high
sensitivity).
Behind the numerical values, there is an evaluated, meaningful
combination of the control parameters
“Dead band” and “Prop
band
” concealed.
The value tables can be found on the following pages.
The sensitivity value can be set separately for each type of
sensor and will then, when a sensor is changed, be
automatically loaded.
Should the MOBA-Matic operate roughly in automatic mode, then
the sensitivity on the corresponding digital controller must be
reset. If the MOBA-Matic operates too sluggishly in automatic
mode, then sensitivity must be increased on the corresponding
digital controller.
Your MOBA dealer has the possibility to amend the basic setting of
the digital controller in such a way that instead of the parameter
“Sensitivity”, the control parameters “Dead band” and “Prop band”,
which are concealed behind this parameter, can be displayed.
These can then be individually adjusted by trained personnel.
Summary of Contents for MOBA-Matic MMC-1000
Page 7: ...Table of contents 7 12 Declaration of conformity 161 ...
Page 79: ...Operation 79 Graphical representation of the user menu ...
Page 161: ...Declaration of conformity 161 12 Declaration of conformity ...
Page 162: ...162 Declaration of conformity ...
Page 163: ...Declaration of conformity 163 ...
Page 164: ...164 Declaration of conformity ...
Page 165: ...Declaration of conformity 165 ...
Page 166: ...166 Declaration of conformity ...
Page 167: ...Declaration of conformity 167 ...
Page 168: ...168 Declaration of conformity ...
Page 171: ...Notes ...