background image

25

Digital Pirani vacuum Sensor System

Product Warranty

Extent of the Warranty

MKS Instruments, Inc., HPS

®

 Products, Inc., warrants the HPS

®

 Products Series 945

Digital Pirani Vacuum Sensor System and its accessories to be free from defects in
materials and workmanship for one (1) year from the date of shipment by HPS

®

 or

authorized representative to the original purchaser (PURCHASER). Any product or parts of
the product repaired or replaced by HPS

®

 under this warranty are warranted only for the

remaining unexpired part of its one (1) year original warranty period. After expiration of the
applicable warranty period, the PURCHASER shall be charged HPS

®

 current prices for parts

and labor, plus any transportation for any repairs or replacement.

ALL EXPRESS AND IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES

OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED
TO THE WARRANTY PERIOD. NO WARRANTIES, EXPRESS OR IMPLIED, WILL APPLY
AFTER THIS PERIOD.
Warranty Service

The obligations of HPS

®

 under this warranty shall be at its option: (1) to repair, replace, or

adjust the product so that it meets applicable product specifications published by HPS

®

 or

(2) to refund the purchase price.
What Is Not Covered

The product is subject to above terms only if located in the country of the seller from

whom the product was purchased. The above warranties do not apply to:

I.   Damages or malfunctions due to failure to provide reasonable and necessary

maintenance in accordance with HPS

®

 operating instructions.

II.  Damages or malfunctions due to chemical or electrolytic influences or use of the

product in working environments outside the specification.

III. Fuses and all expendable items which by their nature or limited lifetime may not

function for a year. If such items fail to give reasonable service for a reasonable period of
time within the warranty period of the product; they will, at the option of HPS

®

, be repaired or

replaced.

IV. Defects or damages caused by modifications and repairs effected by the original

PURCHASER or third parties not authorized in the manual.
Condition of Returned Products

HPS

®

 will not accept for repair, replacement, or credit any product which is asserted to be

defective by the PURCHASER, or any product for which paid or unpaid service is desired, if
the product is contaminated with potentially corrosive, reactive, harmful, or radioactive
materials, gases, or chemicals.

When products are used with toxic chemicals, or in an atmosphere that is dangerous to

the health of humans, or is environmentally unsafe, it is the responsibility of the
PURCHASER to have the product cleaned by an independent agency skilled and approved
in the handling and cleaning of contaminated materials before the product will be accepted
by HPS

®

 for repair and/or replacement.

In the course of implementing this policy, HPS

®

 Customer Service Personnel may inquire

of the PURCHASER whether the product has been contaminated with or exposed to
potentially corrosive, reactive, harmful, or radioactive materials, gases, or chemicals when
the PURCHASER requests a return authorization. Notwithstanding such inquiries, it is the
responsibility of the PURCHASER to ensure that no products are returned to HPS

®

 which

have been contaminated in the aforementioned manner.
Other Rights and Remedies

I.   These remedies are exclusive. HPS

®

 SHALL NOT BE LIABLE FOR

CONSEQUENTIAL DAMAGES, FOR ANTICIPATED OR LOST PROFITS, INCIDENTAL
DAMAGES OR LOSS OF TIME, OR OTHER LOSSES INCURRED BY THE PURCHASER
OR BY ANY THIRD PARTY IN CONNECTION WITH THE PRODUCT COVERED BY THIS
WARRANTY, OR OTHERWISE. Some states do not allow exclusion or limitation of incidental
or consequential damage or do not allow the limitation on how long an implied warranty lasts.
If such laws apply, the limitations or exclusions expressed herein may not apply to
PURCHASER.

II.  Unless otherwise explicitly agreed in writing, it is understood that these are the only

written warranties given by HPS

®

. Any statements made by any persons, including

representatives of HPS

®

, which are inconsistent or in conflict with the terms of the warranty

shall not be binding on HPS

®

 unless reduced to writing and approved by an authorized

officer of HPS

®

.

III. This warranty gives PURCHASER specific legal rights, and PURCHASER may also

have other rights which vary from state to state.

IV.  For HPS

®

 products sold outside of the U.S., contact your MKS representative for

warranty information and service.
Warranty Performance

To obtain warranty satisfaction, contact the following: MKS  Instruments, Inc., HPS

®

Products, Inc., 5330 Sterling Drive, Boulder, CO 80301, USA at phone number
(303) 449-9861. You may be required to present proof of original purchase.

Summary of Contents for HPS 945 Series

Page 1: ...HPS Products Series 945 Digital Pirani Vacuum Sensor System OPERATION AND MAINTENANCE MANUAL...

Page 2: ......

Page 3: ...Digital Pirani Vacuum Sensor System HPS Products Series 945 Digital Pirani Vacuum Sensor System July 1999 Part 109450020 Rev A1...

Page 4: ...and the serial number is located on the back panel of the controller 1999 by MKS Instruments Inc HPS Products Inc All rights reserved Is a registered trademark of MKS Instruments Inc HPSTM Products In...

Page 5: ...Pirani System 10 Pirani Sensor Installation 10 Location 10 Orientation 10 Contamination 10 Vacuum Connection 10 Pirani Controller Installation 11 Controller Mounting 11 Connecting the Sensor to the C...

Page 6: ...ting and Service 22 Cleaning the Pirani Controller Front Panel 22 Cleaning the Pirani Sensor 23 Testing the Pirani Sensor 23 Accessories 24 Product Warranty 25 Notes 26 Appendix A How the Series 945 P...

Page 7: ...5 Digital Pirani Vacuum Sensor System User s Manual The Series 945 System s Pirani Sensor and its connecting cable are sold separately Please refer to page 24 for necessary ordering information If any...

Page 8: ...identify other information in this manual that is essential to highlight or useful in achieving optimal performance from your Series 945 Pirani System CAUTION Risk of electrical shock CAUTION Refer to...

Page 9: ...r to page 20 for use with other gases In a system which is filled from a pressurized source install a safety relief valve or burst disc to safely limit pressure Turn off power to the Controller before...

Page 10: ...current rating Only qualified personnel should change line voltage or fuse ratings if required Outside of the U S use only a detachable cord set that has conductors with a cross sectional area equal t...

Page 11: ...ratureRange 10 to 55 C 14 to 131 F OperatingHumidity 80 maximum noncondensing InsulationCoordination Installation Overvoltage Category II Pollution Degree 2 Number of Channels 1 Front Panel Controls 2...

Page 12: ...entation Any Reproducibility 5 of indicated pressure Tconst Materials Exposed to Vacuum SS 304 platinum alumina ceramic silver brazing alloy nickel 200 Internal Volume 0 5 in 3 8 0 cm3 maximum Operati...

Page 13: ...w Set Point Push buttons Set Point Adjustment Potentiometers LED Set Point Indicators Atmospheric Adjustment Potentiometer Zero Adjustment Potentiometer Power Cord Inlet w Fuse Holder Panel Mounting F...

Page 14: ...ng the relay set points Sensing abnormal pressure and taking appropriate security measures using the relay set points Controlling system pressure using the analog output as input to an automatic press...

Page 15: ...panel cutout or stands alone All controls even the power switch are conveniently accessed from the front panel and cable connections are hidden to the rear of the Controller The Series 945 Pirani Cont...

Page 16: ...e s filament wire and cause the calibration to shift Install the Sensor with the vacuum port facing down whenever possible to prevent particulates falling or liquids flowing into it Using a screen or...

Page 17: ...the Controller with at least 1 inch left open above and below the perforatedpanels An optional hardware kit shown below is also available for mounting the Controller into a standard DIN cutout in a pa...

Page 18: ...sor or Controller Pin 6 of the octal socket is intentionally shorter as a safety measure When the cable is connected or disconnected from the Sensor this feature prevents a voltage overload on the Sen...

Page 19: ...he following time lag fuses T 0 16 A 5 mm x 20 mm 90 to 130 VAC T 0 063 A 5 mm x 20 mm 210 to 250 VAC 4 Close and secure the fuse holder drawer AccessoryConnector Relay set point contacts and the anal...

Page 20: ...C and the resistance R are calculated by the equations C I 2 1 x 107 and R E 10Ia where C is in farads R is in ohms I is DC or ACpeak load current in amperes E is DC or ACpeak source voltage in volts...

Page 21: ...Nitrogen Argon Helium Torr Pascal Voltage Nitrogen Argon Helium 1 0E 04 1 3E 02 0 211 0 211 0 211 5 0E 04 6 7E 02 0 217 0 215 0 217 1 0E 03 1 3E 01 0 225 0 220 0 224 2 5E 03 3 3E 01 0 246 0 234 0 243...

Page 22: ...Sensor Adjustment Series 945 Pirani Controllers and their Sensors are calibrated at HPS However instances in which user calibration will be required are After installation on your system the Controll...

Page 23: ...icrons L0 4 for mbar or L0 2 for Pa If the display shows TL 4 Torr turn the Vac potentiometer clockwise until L0 4 Torr is displayed If the reading is 1 4 Torr or higher turn the Vac potentiometer cou...

Page 24: ...uld be at least 6 Hz 150 msec conversion time A resolution of 12 bits is needed corresponding to 1 22 mV per bit The A D converter should have a differential input to prevent ground currents from affe...

Page 25: ...high vacuum pump such as a diffusion or turbo pump if possible ion and cryo pumps are not recommended Leak testing can be done with a mechanical pump however cyclical variations in pressure may resul...

Page 26: ...e page A 1 Theory of a Thermal Conductivity Sensor Since the Series 945 Pirani System s Sensor is such a gauge the voltage output depends upon the gas measured When used with gases other than nitrogen...

Page 27: ...ermine the voltage pressure relationship for gases which are not shown in the graph or table you need to calibrate the Series 945 Pirani System with this gas This calibration requires a gas independen...

Page 28: ...r too low No analog output voltage and no display No analog output voltage but set points functional Set point relay will not operate Display shows nc 1 Contaminated Sensor 2 Gas other than air is use...

Page 29: ...utput Replace the Sensor if it becomes contaminated see Accessories p 24 Testing the Pirani Sensor This test is for function only Slight Sensor damage by contamination or rough handling can affect cal...

Page 30: ...1 8 NPT M with Compression Seal Option 103150011 15 mm x 30 mm Tubing 103150016 18 mm x 30 mm Tubing 103150018 Power Cord 115 VAC 103150001 Seal Centering Ring Assemblies with Screen KF 16 SST Viton 1...

Page 31: ...for which paid or unpaid service is desired if the product is contaminated with potentially corrosive reactive harmful or radioactive materials gases or chemicals When products are used with toxic che...

Page 32: ...26 Digital Pirani vacuum Sensor System Notes...

Page 33: ...loss and radiation but not eliminate these terms A Pirani sensor may be operated at constant current voltage or resistance equivalent to temperature at the sensor wire The Series 945 Pirani System s...

Page 34: ...a fairly low output impedance it is best to measure the analog output signal with an instrument having at least 1 MW of input impedance Set Point Relays A reference voltage and op amp form a precisio...

Page 35: ...A 3 Digital Pairani Vacuum Sensor System Notes...

Page 36: ...A 4 Digital Pairani Vacuum Sensor System...

Page 37: ......

Page 38: ......

Reviews: