3  Installation 

3.1  Unpacking 

The ESP302-GPIB-ADPT is delivered in packaging designed for safe transport. When unpacking, 
check the unit for signs of shipping damage (damaged box, scratches, dents, etc...) If the unit is 
damaged or fails to meet specifications, notify MKS l Newport representative immediately. 

3.2  Shipment verification 

3.2.1 

Included accessories 

The following items should be included with your unit: 

 

Universal AC/DC Power A 4 adaptation plugs 

 

Instruction Manual 

3.2.2 

Additional accessories 

The following items should be provided separately: 

 

Special female SUB-D9 to male SUB-D15HD serial cable; possibly: 

o

 

Newport ESP302-CAB-1.2 Serial cable 1.2-meter long or, 

o

 

Newport ESP302-RS232 adaptor (+ standard serial 9P straight cable, not null modem). 

 

Standard GPIB cable 

3.3  Mounting conditions 

If the module is to be panel mounted, use the dimensions shown in Figure 3 to drill four mounting holes 
in the panel. Limit the screw length to 0.25 inches in the ESP302-GPIB-ADPT. 

3.4  CONNECTIONS 

3.4.1 

GPIB Interface and Connector J2 

The ESP302-GPIB-ADPT has a standard 24-pin, female GPIB connector with metric lock studs that 
accepts stacked and straight-in GPIB connectors. Use any GPIB cable to connect your GPIB controller 
to the ESP302-GPIB-ADPT. 

 

Figure 4: GPIB connector J2 

Summary of Contents for ESP302-GPIB-ADPT

Page 1: ...ESP302 GPIB ADPT ESP302 GPIB to Serial Adaptor User s Manual A1387A FAX 1 949 253 1680 WWW NEWPORT COM 1771 Deere Avenue Irvine CA 92606 United States 1 949 863 3144...

Page 2: ...anical including photocopying and recording or by any information storage or retrieval system except as may be expressly permitted in writing by MKS Instruments Inc This document is provided for infor...

Page 3: ...3 2 United Kingdom Conformity Assessed Mark 11 1 3 3 Waste Electrical and Electronic Equipment WEEE Mark 11 1 4 Cautions 11 2 Description 12 2 1 Introduction 12 2 2 Overview 12 2 3 Protection of confi...

Page 4: ...or J1 18 3 4 3 Power Connections 18 3 5 GPIB Port Configuration 19 3 5 1 Preparation 19 3 5 2 Starting communication 20 3 5 3 GPIB address setting 21 4 Operation 22 4 1 Introduction 22 4 2 Operation w...

Page 5: ...2 ESP302 GPIB ADPT Outline Dimensions 16 Figure 3 GPIB connector J2 17 Figure 4 RS 232 Serial connector J1 18 Figure 5 PWR input 19 Figure 6 ESP302 GPIB ADPT GPIB Port Connection 19 Figure 7 LEDs 20...

Page 6: ...rvice facility Repairs will be made and the instrument returned freight prepaid Repaired products are warranted for the remainder of the original warranty period or 90 days whichever occurs last Limit...

Page 7: ...7 ESP302 GPIB ADPT A1387A0 EDH0429En1010 11 21 USER s MANUAL EU Declaration of Conformity...

Page 8: ...8 ESP302 GPIB ADPT A1387A0 EDH0429En1010 11 21 USER s MANUAL UK Declaration of Conformity...

Page 9: ...d Related Materials These restrictions shall not apply to information 1 generally known to the public or obtainable from public sources 2 readily apparent from the keyboard operations visual display o...

Page 10: ...re maintained SERVICE BY QUALIFIED PERSONNEL ONLY Operating personnel must not remove instrument covers Component replacement and internal adjustments must be made by qualified service personnel only...

Page 11: ...waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For information about where th...

Page 12: ...connecting Newport ESP302 Motion Controller equipped with a serial port to a GPIB bus for users who want to drive it with an IEEE 488 interface 2 2 Overview The ESP302 GPIB ADPT is controlled from the...

Page 13: ...GPIB bus are placed in the serial transmit buffer and outputted on the selected serial port Serial characters are received in the serial receive buffer When the ESP302 GPIB ADPT senses it had received...

Page 14: ...receivers and is designed to operate as a DTE device with up to 50 feet of cable Signals Txd RxD RTS CTS and Ground Transmit 6 Vdc Logic 0 Data 0 or Control signals On Levels 6 Vdc Logic 1 Data 1 or...

Page 15: ...lf test which takes about five seconds During self test the ESP302 GPIB ADPT sequentially turns each LED on and off It then shows its current GPIB device address by blinking the appropriate front pane...

Page 16: ...H 15 52 cm L x 9 88 cm W x 2 87 cm H Weight 1 lbs 0 45 kg including adapter Temperature Operating 10 C to 55 C Storage 20 C to 70 C Humidity 0 90 RH without condensation Shock Vibration Normal handli...

Page 17: ...he following items should be provided separately Special female SUB D9 to male SUB D15HD serial cable possibly o Newport ESP302 CAB 1 2 Serial cable 1 2 meter long or o Newport ESP302 RS232 adaptor st...

Page 18: ...Figure 5 RS 232 Serial connector J1 Use the special serial cable to connect the ESP302 GPIB ADPT module to the ESP302 port For custom cables check the cable connections to assure that the transmit da...

Page 19: ...ction 4 GPIB address configuration requires an interactive program that can Send the IEEE 488 1 Device Trigger GET command to put the ESP302 GPIB ADPT module into its Command mode Send 488 2 Common Co...

Page 20: ...88 1 GET Trigger command to the ESP302 GPIB ADPT module to switch to Command mode Advanced menu Triggers tab Assert Trigger button in VISA Test Panel Provide a short 30 millisecond pause after the Dev...

Page 21: ...ould display the new address value Write SYST COMM GPIB ADDR Read 5 When done send the ESP302 GPIB ADPT the command to save the new configuration Write SAV 0 Wait 6 seconds and then power cycle the un...

Page 22: ...of the following Messages sent to the ESP302 can terminate by LF or CR LF and or EOI asserted Responses from the ESP302 terminate by CR CR LF and EOI asserted To check correct communication with ESP30...

Page 23: ...ed above messages sent to the ESP302 must terminate by LF and or EOI asserted instead of CR As mentioned above ESP302 messages terminate by CR CR LF instead of CR LF ESP301 SA command should be replac...

Page 24: ...Troubleshooting Table below lists several common fault indications and suggests actions that can be done to either clear the fault or isolate the problem to a faulty piece of equipment Troubleshootin...

Page 25: ...test will continue until it is complete but the RDY LED will remain off If a self test failure occurs turn the unit off for 10 seconds and turn power back on If the failure persists refer to paragraph...

Page 26: ...Bit Weight Event Description 7 128 PON The Power on event occurs at power turn on and can be used to signal a power off on occurrence 6 64 SRQ GPIB SRQ line asserted 5 32 Cmd Command Error Command no...

Page 27: ...________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________...

Page 28: ...t com Europe MICRO CONTROLE Spectra Physics S A S 7 rue des Plantes 45340 Beaune la Rolande France Sales Europe EMEAI Tel 49 0 6151 708 0 e mail germany newport com Sales France Tel 33 0 1 60 91 68 68...

Reviews: