Service manual
Rearrangement of the gas type
6.x–20.x
To convert to another gas type, the burner restrictor must be changed. The restrictors with a restrictor
table are stored in a plastic bag behind the left side wall.
➢
Close the on site gas valve.
➢
Disconnect the unit from the power supply
(remove fuses or pull the connection-plug)
➢
Unscrew the two screws which are located
down on the left to remove the left side
panel.
➢
Unscrew the three screws of the gas valve.
➢
Remove gas valve.
➢
Remove gas restrictor with the seal [1]
➢
Select a restrictor with the help of the
table and refit it by using an
undamaged
seal. [2].
➢
Set up and mount the gas valve.
➢
Open the on site gas valve.
➢
Switch on the power supply
➢
After the conversion continue with
leak
testing
,
checking of the connection
pressure
and
calibration of the
CO2/CO-values.