Service manual
CO
2
value calibration
6.x–20.x Gas
Basics
Definition of CO2 (carbon dioxide) and CO (carbon monoxide):
Carbon dioxide is a colourless and odourless gas and supplies a chemical union made of carbon and
oxygen. Carbon dioxide arises at the burning of substances containing carbon (gasses) if enough
oxygen is available. At an oxygen deficiency CO (carbon monoxide) arises. CO is a color- and
odourless, poisonous gas which can lead to death!
CO
2
value calibration
Caution: This adjustment is crucial for the safe operation of the appliance. After leak testing, the CO
2
content of the exhaust gas requires calibration and the CO content is to be checked.
Select CO
2
value calibration menu
➢
Switch the unit with the ON/OFF Button on.
➢
Press the Flexi Button.
➢
The upper display shows the first menu
CL
or
CLE
.
➢
Choose Par (Parameter) with the upper knob and
press the Start/Stop button.
➢
The upper display shows
PAS
(Password).
➢
The lower display shows
0
.
➢
Enter password
999
with the lower knob and press the
Start/Stop button.
➢
CO2
upper display.
➢
The lower display shows a flashing
Hi
and at two
chamber units
Hi1
for the upper chamber (20.x).
➢
It is possible to switch with the lower knob between
high power (
Hi
,
Hi1
,
Hi2
) and low power (
Lo
,
Lo1
,
Lo2
).
Note for two chamber units::
Hi1 / Lo 1 = 20.x, upper chamber (burner)
Hi2 / Lo 2 = 20.x, lower chamber (burner)