4.3 Power blackout auto restart function
(1)
Power blackout auto restart function is a function that records the operational status of the air-conditioner immediately prior to it
being switched off by a power cut, and then automatically resumes operations at that point after the power has been restored.
(2)
The following settings will be cancelled:
(a)
Timer settings
(b)
High-power operations
Notes (1) The power blackout auto restart function is set at on when the air-conditioner is shipped from the
factory. Consult with your dealer if this function needs to be switched off.
(2) When power failure ocurrs, the timer setting is cancelled. Once power is resumed, reset the timer.
(3) If the jumper wire (J7) “AUTO RESTART” is cut, auto restart is disabled. (See the diagram at right)
Jumper wire (J7)
4.4 Custom cord switching procedure
If two wireless remote controls are installed in one room, in order to prevent wrong operation
due to mixed signals, please modify the printed circuit board in the indoor unit’s control box
and the remote control using the following procedure. Be sure to modify both boards. If only
one board is modified, receiving (and operation) cannot be done.
(1)
Modifying the indoor unit’s printed circuit board
Take out the printed circuit board from the control box and cut off jumper wire (J6)
using wire cutters.
After cutting of the jumper wire, take measures to prevent contact with the other the lead
wires, etc.
(2)
Modifying the wireless remote control
(a) Remove the battery.
(b) Cut the jumper wire shown in the figure at right.
Jumper wire (J6)
Cut
Summary of Contents for SRK10CFV-4; SRK13CFV-4
Page 2: ...TECHNICAL MANUAL...
Page 34: ...PARTS LIST INDOOR UNIT SRK10CFV 4 SRK13CFV 4 OUTDOOR UNIT SRC10CFV 4 SRC13CFV 4...
Page 43: ...CRBE0233 1 7 2 16 3 7 4 5 6 15 8 14 12 10 13 11 18 17 17 17 9 PANEL FAN ASSY 41...
Page 47: ...CRBE0239 1 7 2 16 3 7 4 5 6 15 8 14 12 10 13 11 17 17 17 9 PANEL FAN ASSY 45...
Page 51: ...ROOM AIR CONDITIONING TECHNICAL MANUAL PARTS LIST Manual No 06 SRK T 056...