APPENDICES
Appendix 2 Link Special Register (SW) List
App
- 17
9
DE
DICA
T
E
D
INS
T
RUCT
IONS
10
T
R
OUB
L
E
S
HO
OT
IN
G
APPENDI
CES
INDEX
Table App.4 Link special register (SW) list
No.
Name
Description
Availability
Control
station
Normal
station
SW0000
Link stop/startup
direction
Sets station to stop or start cyclic transmission.
00
H
: Own station
01
H
: All stations
02
H
: Specified station
03
H
: Specified group
80
H
: Own station (forced link startup)
81
H
: All stations (forced link startup)
82
H
: Specified station (forced link startup)
83
H
: Specified group (forced link startup)
The cyclic transmission stop/startup can be performed by System link startup
(SB0002) or System link stop (SB0003).
SW0001 to
SW0008
Sets the station No. to stop or start up cyclic transmission when 02
H
or 82
H
is
set in Link stop/startup direction (SW0000).
0: Stop or startup not directed
1: Stop or startup directed
SW0009
Arrival monitoring time
(RIRD/RIWT instruction)
Specify the monitoring time required for instruction completion.
If an instruction is not completed within this time, it will be resent the number
of times specified in SW000B.
0: 10 seconds (default)
1 to 360: 1 to 360 seconds
If a value other than the above is specified, 360 seconds will be applied.
SW000B
Number of resends
(RIRD/RIWT instruction)
Specify the number of times the instruction is to be resent when it is not
completed within the monitoring time specified in SW0009.
0: Not resend (default)
1 to 7: Once to 7 times
If a value other than the above is specified, 7 times will be applied.
SW0012 to
SW0013
Group specification for
link stop/startup
Sets the group No. to stop or start up cyclic transmission when 03
H
or 83
H
is
set in Link stop/startup direction (SW0000).
0: Stop or startup not directed
1: Stop or startup directed
SW0020
Module status
Stores the CC-Link IE controller network module status.
0: Normal
1 or later: Error (
FF
H
: Module error
SW0001
SW0002
SW0003
SW0004
SW0005
SW0006
SW0007
SW0008
16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
-
-
-
-
-
-
-
-
120 119 118 117 116 115 114 113
Each number in the table represents station No.
SW0012
SW0013
16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
Each number in the table represents group No.
Link special register (SW): SW0000 to SW0020
Summary of Contents for QJ71GP21-SX
Page 1: ......
Page 2: ......
Page 644: ...App 94 Appendix 6 External Dimensions Appendix 6 2 QJ71GP21S SX APPENDICES Memo ...
Page 649: ......
Page 650: ......