3 -
14
3.
SYSTEM CONFIGURATION
Computer link
module
AJ71UC24
*2
Link module that communicates data with a
computer.
Transmission speed: 300bps to 19.2kbps
RS-232C, RS-422: one channel each,
compatible with RS485
32 (special 32 points)
0.3
–
Maximum 6
modules can be
used for one
CPU module.
Intelligent
communication
module
AD51H-S3
AD51H-BASIC, maximum of 8 tasks executes
data communication with a PLC or a computer,
and monitoring control status.
Data communication with a computer can be
executed by any format.
RS-232C: 2 channels, RS-422, Parallel: one
channel each
48
1.0
–
Host controller
high-speed link
module
AJ71C23-S3
*2
Link module that sends/receives data at high
speed to/from a computer.
Transmission speed: 500kbps
RS-422: one channel each
32 (special 32 points)
1.5
–
Multidrop data link
module
AJ71C22-S1
Sends and receives bit data to maximum 8
slave stations to which it is connected in a
multidrop system.
Used for the master station of a multidrop link.
Transmission speed: 38.4kbps
RS-422: one channel each
32 (special 32 points)
1.4
–
A0J2C25
Used for a remote I/O station of a multidrop
link.
–
–
–
A0J2C214(S1)
Used for a local station in a multidrop link.
In A0J2CPU and A0J2HCPU systems,
A0J2C214 can also be used as the master
station in computer links and multidrop data links
64 points
0.3
–
CC-Link system
master/local
module
AJ61QBT11
For CC-Link system master and local stations
When used as the master station, the module
controls maximum 64 remote I/O stations.
When a local station is used, the module
occupies 1 or 4 station(s).
32 (special 32 points)
0.45
–
For use with
QnACPU only
MELSECNET/
MINI-S3 data link
module
AJ71PT32-S3
For MELSECNET/MINI-S3 master stations
(max. 64 stations). Performs remote I/O and
remote terminal control of a total of 512 I/O
points.
I/O dedicated mode
32 (special 32 points)
0.34
–
AJ71T32-S3
Expanded mode
48 (special 48 points)
B/NET interface
module
AJ71B62-S3
Used for B/NET transmission terminal control.
Up to 63 stations can be controlled per module.
32 (special 32 points)
0.17
–
Interrupt module
AI61
Used to designate execution of interrupt
programs (16 interrupt inputs).
32 (special 32 points)
0.14
–
Only one
module can be
used per CPU.
AI61-S1
Product for changing time to turn ON/OFF A61
Product Name
Model Name
Description
Number of Occupied
Points (points)
[I/O Allocation
Module Type]
Current Consumption
Remark
5VDC(A) 24VDC(A)
First half:
empty 16 points
Second half:
special 32
points
Summary of Contents for Q2ACPU
Page 1: ......
Page 2: ......
Page 221: ...12 12 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Page 222: ...12 13 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU ...
Page 237: ...12 28 12 OVERVIEW OF PROCESSING PERFORMED BY THE QnACPU MEMO ...
Page 271: ...16 13 16 POWER SUPPLY MODULE 4 Names and description of parts of the A66P ...
Page 343: ...21 21 13 MAINTENANCE AND INSPECTION 21 4 2 Replacement of the fuse for an output module ...
Page 357: ...22 12 22 TROUBLESHOOTING ...
Page 359: ...22 14 22 TROUBLESHOOTING MEMO ...
Page 429: ...App 32 APPENDICES Trigonometric function Classification Symbol Description ...
Page 537: ...App 140 APPENDICES REMARK 1 Message 1 An error code is displayed in 2 Alert 1 3 Alert 2 ...
Page 539: ...App 142 APPENDICES 2 Q2ACPU Q2ACPU S1 modules Unit mm inch ...
Page 541: ...App 144 APPENDICES 2 A66P power supply module Unit mm inch ...
Page 543: ...App 146 APPENDICES 3 A35B base unit 4 A38B A38HB A38HBEU base unit Unit mm inch Unit mm inch ...
Page 567: ...MEMO ...
Page 569: ......
Page 570: ......