252
RY25
CH1
Selected
counter function
start command
• Turn on this signal to perform the selected counter functions.
• When Count Disable Function (0) or Periodic Pulse Counter Function (3) is
selected for CH
Counter function selection (address: 0126
H
, 0146
H
), this signal
is valid while being on.
• When Sampling Counter Function (2) or Latch Counter Function (1) is selected for
CH
Counter function selection (address: 0126
H
, 0146
H
), this signal becomes
valid at the rising edge (off to on).
• When Count disable/Preset/replace Function (4) or Latch counter/Preset/replace
Function (5) is selected for CH
Counter function selection (address: 0126
H
,
0146
H
), this signal is invalid.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY3D
CH2
RY26
CH1
Cam switch
execute
command/PWM
output start
command
• Turn on this signal to execute the cam switch function.
• Turn on this signal to start PWM output.
RY3E
CH2
RY27
CH1
Setting change
request
(Sampling
counter/Periodic
pulse counter)
• Turn on this signal to activate the changes of CH
Time unit setting (Sampling
counter/Periodic pulse counter) (RWw16, RWw2E) and CH
Cycle setting
(Sampling counter/Periodic pulse counter) (RWw17, RWw2F).
• When this signal is turned on, the setting values written into the above remote
registers (RWw) are reflected to the high-speed counter module. After the setting
values are reflected, CH
Setting change completed (Sampling counter/Periodic
pulse counter) (RX27, RX3F) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY3F
CH2
RY28
Update flag
reset command
(Latch count
value)
• Turn on this signal to reset CH
Update flag (Latch count value) (RX29, RX41).
• When this signal is turned on, CH
Update flag (Latch count value) (RX29, RX41)
turns off. After resetting is completed, CH
Update flag reset completed (Latch
count value) (RX28, RX40) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
CH1
Update flag
reset command
(Sampling count
value)
• Turn on this signal to reset CH
Update flag (Sampling count value) (RX29,
RX41).
• When this signal is turned on, CH
Update flag (Sampling count value) (RX29,
RX41) turns off. After resetting is completed, CH
Update flag reset completed
(Sampling count value) (RX28, RX40) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY40
CH2
Update flag
reset command
(Periodic pulse
count value)
• Turn on this signal to reset CH
Update flag (Periodic pulse count value) (RX29,
RX41).
• When this signal is turned on, CH
Update flag (Periodic pulse count value)
(RX29, RX41) turns off. After resetting is completed, CH
Update flag reset
completed (Periodic pulse count value) (RX28, RX40) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY2A
CH1
Latch count
value update
flag reset
command
(Latch counter
input terminal)
• Turn on this signal to reset CH
Latch count value update flag (Latch counter
input terminal) (RX2B, RX43).
• When this signal is turned on, CH
Latch count value update flag (Latch counter
input terminal) (RX2B, RX43) turns off. After resetting is completed, CH
Latch
count value update flag reset completed (Latch counter input terminal) (RX2A,
RX42) turns on.
(For the overview of the operation, refer to Page 236, Appendix 1.1.)
RY42
CH2
Remote
output
(RY) No.
Signal name
Operation