245
APPENDICES
A
Appendix 1 Details of R
emote I/O Signa
ls
Appendix 1.1 Details of r
emote input sig
nals
RX2A
CH1
Latch count
value update
flag reset
completed
(Latch counter
input terminal)
• This signal turns on when resetting CH
Latch count value update flag (Latch counter input
terminal) (RX2B, RX43) by CH
Latch count value update flag reset command (Latch
counter input terminal) (RY2A, RY42) is completed.
• This signal turns off when CH
Latch count value update flag reset command (Latch
counter input terminal) (RY2A, RY42) is turned off.
RX42
CH2
RX2B
CH1
Latch count
value update
flag (Latch
counter input
terminal)
• This signal turns on when CH
Latch count value (Latch counter input terminal) (RWr18 to
RWr19, RWr30 to RWr31) is updated.
(
• CH
Latch count value (Latch counter input terminal) (RWr18 to RWr19, RWr30 to RWr31)
is updated without resetting this flag.
• This signal turns off when CH
Latch count value update flag reset command (Latch
counter input terminal) (RY2A, RY42) is turned on.
• Up to
Δ
T
1
*1
delay occurs until this signal turns on after CH
Latch count value (Latch
counter input terminal) (RWr18 to RWr19, RWr30 to RWr31) is updated.
(For the overview of the operation, refer to the description of CH
Latch count value update
flag reset completed (Latch counter input terminal) (RX2A, RX42).)
*1
For
Δ
T
1
, refer to Page 283, Appendix 4.
RX43
CH2
RX2C
Update flag
reset completed
(Measured
frequency
value)
• This signal turns on when resetting CH
Update flag (Measured frequency value) (RX2D,
RX45) by CH
Update flag reset command (Measured frequency value) (RY2C, RY44) is
completed.
• This signal turns off when CH
Update flag reset command (Measured frequency value)
(RY2C, RY44) is turned off.
CH1
RX44
CH2
Update flag
reset completed
(Measured
rotation speed
value)
• This signal turns on when resetting CH
Update flag (Measured rotation speed value)
(RX2D, RX45) by CH
Update flag reset command (Measured rotation speed value)
(RY2C, RY44) is completed.
• This signal turns off when CH
Update flag reset command (Measured rotation speed
value) (RY2C, RY44) is turned off.
(The operation is the same as that of CH
Update flag reset completed (Measured
frequency value) (RX2C, RX44) except the signal name.)
Remote input
(RX) No.
Signal name
Description
CH Latch count value update flag reset command
(Latch counter input terminal)
(RY2A, RY42)
CH Latch count value update flag
(Latch counter input terminal)
(RX2B, RX43)
CH Latch count value update flag reset completed
(Latch counter input terminal)
(RX2A, RX42)
Controlled by the high-speed counter module
Controlled by the program
ON
OFF
ON
OFF
ON
OFF
CH Update flag reset command
(Measured frequency value)
(RY2C, RY44)
CH Update flag
(Measured frequency value)
(RX2D, RX45)
CH Update flag reset completed
(Measured frequency value)
(RX2C, RX44)
Controlled by the high-speed counter module
Controlled by the program
ON
OFF
ON
OFF
ON
OFF
Summary of Contents for NZ2GFCF-D62PD2
Page 1: ......
Page 2: ......
Page 54: ...52 Memo ...
Page 206: ...204 Memo ...
Page 303: ......
Page 304: ......