60
4.1.3
Easy operation mode setting (easy setting mode)
Setting of
Pr. 79 Operation mode selection
according to combination of the start command and speed command can be
easily made.
Operation example Start command: external (STF/STR), frequency command: operate with
Operation Display
1. Screen at power-ON
The monitor display appears.
2. Press and for
0.5s.
3. Turn
until
appears.
(refer to the table below for other settings)
* To use
as a potentiometer,
refer to page 317
.
4. Press
to set.
Flicker ··· Parameter setting complete!!
The monitor display appears after 3s.
REMARKS
is displayed ... Why?
Pr. 79
is not registered in user group with "1" in
Pr. 160 User group read selection
.
Parameter write is disabled with "1" set in
Pr. 77
.
is displayed ... Why?
Setting cannot be changed during operation. Turn the start command (
or
, STF or STR) OFF.
If
is pressed before pressing
, the easy setting mode is terminated and the display goes back to the monitor display. If the
easy setting mode is terminated while
Pr. 79
= "0 (initial setting)," the operation mode switches between the PU operation mode and the
External operation mode. Check the operation mode.
Reset can be made with
.
The priorities of the frequency commands when
Pr. 79
= "3" are "Multi-speed operation (RL/RM/RH/REX) > PID control (X14) > terminal
4 analog input (AU) > digital input from the operation panel".
Flickering
Operation Panel Indication
Operation Method
Start command
Frequency command
,
*
External
(STF, STR)
Analog
voltage input
External
(STF, STR)
*
,
Analog
voltage input
Flickering
Flickering
Flickering
Flickering