8. Function Selection

[Detailed setting]

[4]–1. CHANGE LANGUAGE setting

The language that appears on the dot display can be selected.

• Press the [

MENU] button 

G

 to change the language.

1

 English (GB), 

2

 German (D), 

3

 Spanish (E), 

4

 Russian (RU),

5

 Italian (I), 

6

 Chinese (CH), 

7

 French (F), 

8

 Japanese (JP)

Refer to the dot display table.

[4]–2. Function limit

(1) Operation function limit setting (operation lock)

• To switch the setting, press the [

ON/OFF] button 

D

.

1

  no1: Operation lock setting is made on all buttons other than the

[

ON/OFF] button.

2

 no2: Operation lock setting is made on all buttons.

3

 OFF (Initial setting value): Operation lock setting is not made.

* To make the operation lock setting valid on the normal screen, it is

necessary to press buttons (Press and hold down the [FILTER] and
[

ON/OFF] buttons at the same time for two seconds.) on the

normal screen after the above setting is made.

(2) Use of automatic mode setting

When the remote controller is connected to the unit that has automatic
operation mode, the following settings can be made.
• To switch the setting, press the [

ON/OFF] button 

D

.

1

ON (Initial setting value):
The automatic mode is displayed when the operation mode is
selected.

2

OFF:
The automatic mode is not displayed when the operation mode
is selected.

(3) Temperature range limit setting

After this setting is made, the temperature can be changed within the
set range.
• To switch the setting, press the [

ON/OFF] button 

D

.

1

LIMIT TEMP COOL MODE:
The temperature range can be changed on cooling/dry mode.

2

LIMIT TEMP HEAT MODE:
The temperature range can be changed on heating mode.

3

LIMIT TEMP AUTO MODE:
The temperature range can be changed on automatic mode.

4

OFF (initial setting): The temperature range limit is not active.

* When the setting, other than OFF, is made, the temperature range

limit setting on cooling, heating and automatic mode is made at the
same time. However, the range cannot be limited when the set
temperature range has not changed.

• To increase or decrease the temperature, press the [

TEMP. (

)

or (

)] button 

F

.

• To switch the upper limit setting and the lower limit setting, press the

[

] button 

H

. The selected setting will flash and the temperature

can be set.

• Settable range

Cooling/Dry mode:

Lower limit:19

°

C ~ 30

°

C

Upper limit:30

°

C ~ 19

°

C

Heating mode:

Lower limit:17

°

C ~ 28

°

C

Upper limit:28

°

C ~ 17

°

C

Automatic mode:

Lower limit:19

°

C ~ 28

°

C

Upper limit:28

°

C ~ 19

°

C

* The settable range varies depending on the unit to connect (Mr.

Slim units, CITY MULTI units, and intermediate temperature units)

(4) Use of automatic filter elevation panel up/down operation mode set-

ting
For this model, this function is not available.

(5) Use of fixed airflow direction mode setting

For this model, this function is not available.

[4]–3. Mode selection setting

(1) Remote controller main/sub setting

• To switch the setting, press the [

ON/OFF] button 

D

.

1

Main:

The controller will be the main controller.

2

Sub:

The controller will be the sub controller.

(2) Use of clock setting

• To switch the setting, press the [

ON/OFF] button 

D

.

1

ON:

The clock function can be used.

2

OFF:

The clock function cannot be used.

(3) Timer function setting

• To switch the setting, press the [

ON/OFF] button 

D

 (Choose one

of the followings.).

1

WEEKLY TIMER (initial setting value):
The weekly timer can be used.

2

AUTO OFF TIMER:
The auto off timer can be used.

3

SIMPLE TIMER:
The simple timer can be used.

4

TIMER MODE OFF:
The timer mode cannot be used.

* When the use of clock setting is OFF, the “WEEKLY TIMER” cannot

be used.

(4) Contact number setting for error situation

• To switch the setting, press the [

ON/OFF] button 

D

.

1

CALL OFF:
The set contact numbers are not displayed in case of error.

2

CALL **** *** ****:
The set contact numbers are displayed in case of error.
CALL_:
The contact number can be set when the display is as shown on
the left.

• Setting the contact numbers

To set the contact numbers, follow the following procedures.
Move the flashing cursor to set numbers. Press the [

TEMP.

(

) and (

)] button 

F

 to move the cursor to the right (left). Press

the [

CLOCK (

) and (

)] button 

C

 to set the numbers.

[4]–4. Display change setting

(1) Temperature display 

°

C/

°

F setting

• To switch the setting, press the [

 ON/OFF] button 

D

.

1

°

C:

The temperature unit 

°

C is used.

2

°

F:

The temperature unit 

°

F is used.

(2) Suction air temperature display setting

• To switch the setting, press the [

ON/OFF] button 

D

.

1

ON:

The suction air temperature is displayed.

2

OFF:

The suction air temperature is not displayed.

(3) Automatic cooling/heating display setting

• To switch the setting, press the [

ON/OFF] button 

D

.

1

ON:
One of “Automatic cooling” and “Automatic heating” is displayed
under the automatic mode is running.

2

OFF:
Only “Automatic” is displayed under the automatic mode.

KB79H133H01_en.pm6

07.7.11, 9:23 AM

12

Summary of Contents for Mr.Slim SEZ-KD25

Page 1: ...eggere attentamente questi istruzioni di funzionamento prima di avviare l unità per un uso corretto e sicuro della stessa DRIFTSMANUAL Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används DRIFTSMANUAL Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug MANUAL DE OPERAÇÃO Para segurança e utilização co...

Page 2: ...r fire may result Do not stand on or place any items on the unit Do not splash water over the unit and do not touch the unit with wet hands An electric shock may result Do not spray combustible gas close to the unit Fire may result Do not place a gas heater or any other open flame appliance where it will be exposed to the air discharged from the unit Incomplete combustion may result Do not remove ...

Page 3: ...e hour at which time the airflow di rection also changes Room Temperature display Showstheroomtemperature Theroom temperature display range is 8 39 C The display flashes if the temperature is less than 8 C or 39 C or more Louver display Indicates the action of the swing louver Does not appear if the louver is station ary Power On indicator Indicates that the power is on Fan Speed indicator Shows t...

Page 4: ...ons or F C TIMER MON OFF WEEKLY SUN MON TUE WED THU FRI SAT WEEKLY F C C TIME SUN Function Selection of remote controller Set Day Time Standard Control Screens OFF ON Timer Monitor Timer Setup A D C B C B 1 Press the or Set Time button A to show display 2 2 Press the Timer On Off Set Day button 9 to set the day Each press advances the day shown at 3 Sun Mon Fri Sat 3 Press the appropriate Set Time...

Page 5: ...nnot operate indicating an operation state in flashing In this case please set all the indoor units to the same operation mode There might be a case that the indoor unit which is operating in AUTO mode Cannot change over to the operating mode COOL HEAT and becomes a state of standby When indoor unit starts the operation while the defrosting of outdoor unit is being done it takes a few minutes max ...

Page 6: ...s at Steps 3 and 4 will select one of the cells from the matrix illustrated below The remote controller display at left shows how the display would appear when setting Operation 1 for Sunday to the values indicated below 6 Timer 5 6 Ventillation s s s s sFor LOSSNAY combination 5 6 1 For Wired Remote controller To run the ventilator together with the indoor unit Press the ON OFF button 1 The Vent ...

Page 7: ...ps 3 and 4 Note that ON and OFF times cannot be set to the same value 6 To clear the current ON or OFF setting Display the ON or OFF setting see step 3 and then press the Check Clear button 0 so that the time setting clears to at 4 If you want to use only an ON setting or only an OFF setting be sure that the setting you do not wish to use is shown as C C TIME SUN WEEKLY 0 C C TIME SUN WEEKLY 0 7 P...

Page 8: ... is ON setting 5 hours OFF setting 2 hours 3 hours At Timer Start Display shows the timer s OFF setting hours remaining to OFF At 5 hours after timer start The air conditioner comes on and will continue to run until someone turns it off 6 1 3 Auto Off Timer This timer begins countdown when the air conditioner starts and shuts the air conditioner off when the set time has elapsed Available settings...

Page 9: ...se either of the following two lock types 1Lock All Buttons Locks all of the buttons on the remote controller 2Lock All Except ON OFF Locks all buttons other than the ON OFF button Note The Locked indicator appears on the screen to indicate that buttons are cur rently locked How to Lock the Buttons 1 While holding down the Filter button 4 press and hold down the ON OFF button 1 for 2 seconds The L...

Page 10: ... 1 Change Language CHANGE LANGUAGE 2 Function limit FUNCTION SELECTION 3 Mode selection MODE SELEC TION 4 Display change DISP MODE SETTING Item 2 Language setting to display 1 Operation function limit setting operation lock LOCKING FUNCTION 2 Use of automatic mode setting SELECT AUTO MODE 3 Temperature range limit setting LIMIT TEMP FUNCTION 4 Use of automatic filter elevation panel up down operat...

Page 11: ...ection Display mode setting Operation lock setting is not used Initial setting value Operation lock setting is except On Off button Operation lock setting is All buttons The automatic mode is displayed when the operation mode is selected Initial setting value The automatic mode is not displayed when the operation mode is selected The temperature range limit is not active Initial setting value The ...

Page 12: ...C 30 C Upper limit 30 C 19 C Heating mode Lower limit 17 C 28 C Upper limit 28 C 17 C Automatic mode Lower limit 19 C 28 C Upper limit 28 C 19 C The settable range varies depending on the unit to connect Mr Slim units CITY MULTI units and intermediate temperature units 4 Use of automatic filter elevation panel up down operation mode set ting For this model this function is not available 5 Use of f...

Page 13: ...matic mode setting Temperature range limit setting Use of automatic filter elevation panel up down operation mode setting Use of fixed airflow direction mode setting Limit temperature cooling day mode Limit temperature heating mode Limit temperature auto mode Mode selection Remote controller setting MAIN Remote controller setting SUB Use of clock setting Setting the day of the week and time Timer ...

Page 14: ...ukewarm water Take care to rinse off any detergent thoroughly and allow the filters to dry com pletely before putting them back into the unit Caution Do not dry the filters in direct sunlight or by using a heat source such as an electric heater this may warp them Do not wash the filters in hot water above 50 C as this may warp them Make sure that the air filters are always installed Operating the ...

Page 15: ...heard when parts rub against each due to expan sion and contraction from temperature changes The indoor unit draws in air that contains gases produced from the walls carpeting and furniture as well as odors trapped in clothing and then blows this air back into the room If the indoor temperature and the humidity are high this condition may occur when operation starts During defrosting mode cool air...

Page 16: ...ce there may be a refrig erant leak Be sure to ask the service representative whether there is refrigerant leakage or not when repairs are carried out The refrigerant charged in the air conditioner is safe Refrigerant nor mally does not leak however if refrigerant gas leaks indoors and comes into contact with the fire of a fan heater space heater stove etc harmful substances will be generated Inve...

Page 17: ...ipment Guaranteed operating range Indoor Outdoor KD25 KD35 KD50 KD60 KD71 Cooling Upper limit 32 C DB 23 C WB 46 C DB 43 C DB Lower limit 21 C DB 15 C WB 10 C DB Heating Upper limit 27 C DB 24 C DB 18 C WB Lower limit 20 C DB 10 C DB 11 C WB Units should be installed by licensed electric contractor accordingly to local code requirement SEZ KD35VA Cooling Heating 3 5 4 0 11 900 13 600 0 05 0 05 SEZ...

Page 18: ...e 2006 95 EC Electromagnetic Compatibility Directive 89 336 EEC 2004 108 EC This product is designed and intended for use in the residential commercial and light industrial environment HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN KB79H133H01 The product at hand is based on the following EU regulations ...

Reviews: