27 TIMER FUNCTION BLOCKS
27.1 Timer Function Blocks
27
TIMER FUNCTION BLOCKS
27.1
Timer Function Blocks
TIMER_
_M
When the execution condition is established, these function blocks start the timer count to the set time.
Setting data
■
Descriptions, types, and data types
Processing details
■
TIMER_1_FB_M
• When the execution condition of (s1) turns on, counting the current value starts. The timer starts counting from "(s3)
1
ms". When it counts up to "(s2)
1 ms", (d2) turns on. The current measurement value is output into (d1).
• When the execution condition of (s1) turns off, the current value is reset to (s3) and (d2) turns off.
• A value in the range of 0 to 32767 can be specified for (s2).
• A value in the range of -32768 to 32767 can be specified for (s3). However, when a negative value is specified, the initial
value is set to 0.
Ex.
[Ladder example]
[Timing chart]
Ladder diagram
Structured text
(
indicates TIMER_1_FB_M, TIMER_10_FB_M, TIMER_100_FB_M,
TIMER_CONT_FB_M, TIMER_CONTHS_FB_M.)
TIMER_1_FB_M_1(Coil:=s1,Preset:=s2,ValueIn:=s3,ValueOut:=d1,Status:=d2);
TIMER_10_FB_M_1(Coil:=s1,Preset:=s2,ValueIn:=s3,ValueOut:=d1,Status:=d2);
TIMER_100_FB_M_1(Coil:=s1,Preset:=s2,ValueIn:=s3,ValueOut:=d1,Status:=d2);
TIMER_CONT_FB_M_1(Coil:=s1,Preset:=s2,ValueIn:=s3,ValueOut:=d1,Status:=d2);
TIMER_CONTHS_FB_M_1(Coil:=s1,Preset:=s2,ValueIn:=s3,ValueOut:=d1,Status:=
d2);
Argument
Description
Type
Data type
s1
Execution condition (TRUE: Execution, FALSE: Stop)
Input variable
BOOL
s2
Timer set value
Input variable
INT
s3
Timer initial value
Input variable
INT
d1
Timer current value
Output variable
ANY16
d2
Output
Output variable
BOOL
s1
d1
d2
s2
s3
Preset
ValueOut
Status
ValueIn
TIMER_1_FB_M
Coll
1
10
M0
M10
D10
OFF
OFF
M0
Value of D10
M10
10
9 ms
ON
1
Summary of Contents for MELSEC iQ-F FX5 series
Page 1: ...MELSEC iQ F FX5 Series Programming Manual Instructions Standard Functions Function Blocks ...
Page 2: ......
Page 21: ...19 PART 1 PART 1 OVERVIEW Part 1 consists of the following chapter 1 OVERVIEW ...
Page 98: ...96 4 STANDARD FUNCTIONS FUNCTION BLOCKS 4 2 Standard Function Blocks MEMO ...
Page 840: ...838 23 TIME DATA FUNCTIONS 23 4 Division MEMO ...
Page 887: ......