4. CONNECTION TO FUJI PLC
4.6 Device Range that Can Be Set
4 - 19
4
CONNEC
T
ION T
O
FUJI PLC
4.6
Device Range that Can Be Set
The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
POINT
POINT
POINT
Device settings of FUJI FA PLC
(1) When setting a bit device
Set the device using the format of word number
(DEC) + bit No. (0 to F (HEX)).
(2) When setting a word device
For direct access (W24) and user file (W30 to
W109, W9), set as follows.
4.6.1
FUJI MICREX-F Series
Item
Information
Device
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
The uppermost bit is b0 and the lowermost bit is b15.
Information
Displays the device type and setting range which are
selected in [Device].
Network
Set the monitor target of the set device.
Station
No.
Select this item when monitoring the PLC of
the specified station No.
Device name
Setting range
Device No.
representation
Bi
t d
e
v
ice
I/O relay (B)
B0000 to B511F
D
Hexadecimal
Auxiliary relay (M)
M0000 to M511F
Keep relay (K)
K0000 to K063F
Special relay (F)
*1
F0000 to F125F
Annunciator relay
(A)
A0000 to A045F
Differential relay (D)
D0000 to D063F
Link memory (L)
L0000 to L511F
Timer output
(0.01s) (T)
T000 to T511
Decimal
Timer output
(0.1s) (T)
T512 to T999
Counter output (C)
C000 to C511
Word device bit
*5
Specified bit of the following
word devices
Direct access,
user file
―
W
o
rd
device
I/O relay (WB)
WB000 to WB511
Decimal
Auxiliary relay (WM)
WM000 to WM511
Keep relay (WK)
WK000 to WK063
Special relay (WF)
*1
WF000 to WF125
Annunciator relay
(WA)
WA000 to WA045
Bit No.(HEX)
Word No.(DEC)
Device name
Word number
File number
Device name
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......