2. CONNECTION TO HITACHI IES PLC
2.5 PLC Side Setting
2 - 11
2
CONNECTION T
O
HIT
ACH
I
IE
S PLC
2.5
PLC Side Setting
POINT
POINT
POINT
HITACHI IES PLC
For details of the HITACHI IES PLC, refer to the
following manual.
HITACHI IES PLC user's Manual
Directly connecting to the CPU
*1
Indicates only the transmission speeds that can be set on
the GOT side.
*2
The transmission speed setting must be consistent with that
of the GOT side.
For the transmission speed setting on the GOT side, refer to
the following.
2.4.2 Communication detail settings
*3
The setting range varies with the connected PLC.
Connecting to the intelligent serial port
module
(1) For transmission control procedure1
(2) For transmission control procedure2
Item
Set value
Transmission speed
*1*2*3
4800bps, 9600bps,
19200bps, 38400bps
Station No.
0
Data bit
7bit
Stop bit
1bit
Parity bit
Even
Control Method
DTR control
Communication format
RS-232
Sum check
Done
Protocol
transmission control procedure 1
Item
Set value
Transmission speed
19200bps
Station No.
0
Data bit
7bit
Stop bit
1bit
Parity bit
Even
Control Method
None
Communication format
For RS-232 communication:
RS-232 MODE switch 2
For RS-422 communication:
RS-422 MODE switch 2
Sum check
Done
Item
Set value
Transmission speed
19200bps
Station No.
0
Data bit
7bit
Stop bit
1bit
Parity bit
Even
Control Method
None
Communication format
For RS-232 communication:
RS-232 MODE switch 9
For RS-422 communication:
RS-422 MODE switch 9
Sum check
Done
Summary of Contents for GOT2000Series
Page 2: ......
Page 17: ...A 15 REVISIONS WARRANTY...
Page 52: ...1 30 1 PREPARATORY PROCEDURES FOR MONITORING 1 6 Checking for Normal Monitoring...
Page 54: ......
Page 78: ...3 10 3 CONNECTION TO HITACHI PLC 3 6 Device Range that Can Be Set...
Page 100: ...4 22 4 CONNECTION TO FUJI PLC 4 7 Precautions...
Page 174: ...7 24 7 CONNECTION TO YOKOGAWA PLC 7 4 Device Range that Can Be Set...
Page 262: ...9 54 9 CONNECTION TO RKC TEMPERATURE CONTROLLER 9 7 Precautions...
Page 280: ...10 18 10 CONNECTION TO ALLEN BRADLEY PLC 10 4 Device Range that Can Be Set...
Page 296: ...11 16 11 CONNECTION TO GE PLC 11 7 Precautions...
Page 308: ...12 12 12 CONNECTION TO LS INDUSTRIAL SYSTEMS PLC 12 6 Device Range that Can Be Set...
Page 332: ...14 18 14 CONNECTION TO SIEMENS PLC 14 4 Device Range that Can Be Set...
Page 334: ...REVISIONS 2...
Page 337: ......